Electrical Requirements; Wiring Instructions - HotSpring LimeLight GLEAM Owner's Manual

Hide thumbs Also See for LimeLight GLEAM:
Table of Contents

Advertisement

e
r
lectrIcal

WIRING INSTRUCTIONS

Your HOT SPRING spa has been carefully designed to give you maximum
safety against electric shock. Connecting the spa to an improperly wired circuit
will negate many of the spa's safety features. Improper wiring may also cause
electrocution, risk of fire, and other risks of injuries. The HOT SPRING Spa must
be installed to a GFCI of 10 milliamp trip or lower. Please read and follow the
electrical installation requirements and instructions for your specific spa model
completely!
SERVICE NOTE: The HOT SPRING spa is equipped with a power
indicator which, in addition to showing the spa has power to it, has a
diagnostic function as well. It will begin blinking if the heater high-limit
thermostat has tripped. If the power indicator light is blinking, follow
the instructions in the Troubleshooting section to identify and correct
the cause. The power indicator will stop blinking once the problem has
been corrected.
HOT SPRING SPAS MUST BE WIRED IN ACCORDANCE WITH ALL
APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. ALL
ELECTRICAL WORK SHOULD BE DONE BY AN EXPERIENCED,
LICENSED ELECTRICIAN. WE RECOMMEND THE USE OF
APPROPRIATE ELECTRICAL CONDUIT, FITTINGS, AND WIRE FOR
ALL CIRCUITS.
This product requires a 16 amp (FLAIR, BOLT & GLOW) or 20 amp
(GLEAM, PULSE/DL), single phase, 220 - 240 volt, three wire service
(one line, one neutral, one ground). The grounding conductor must be
at least the same gauge as the line conductors. A minimum No. 8.4
mm² solid copper bond may also be required. Additionally, one main
L1, HOT
BROWN
N, NEUTRAL
BLUE
GROUND
GREEN/YELLOW
eQuIrementS
Factory Installed
Terminal Block
Power Jumpers
GFCI BREAKER
16A (FLAIR, BOLT & GLOW Models)
- 2.1mm²
20A (PULSE/DL Model PLSDE) - 4.0
mm²
disconnect switch at least 3 mm separation between contacts must be
used for all electrical circuits to the spa.
NOTE: The GLEAM will require an additional 16 amp breaker in order
to operate the heater and jet pump 3 at the same time. Without the
additional 16 amp breaker, the heater will NOT operate while jet pump
3 is on.
Mount the subpanel according to local codes, but not closer than 1.5
meters away.
CONDUIT INSTALLATION INSTRUCTIONS
1. To connect the electrical service, first remove the screws from the
equipment compartment door.
2. Locate the control box. Loosen the screws on the front of the
control box. Remove the screws and the control box cover.
3. Route the electrical service from the subpanel into the spa equipment
compartment using the cut out in the frame below the door.
4. Connect the supply conduit to the control box and connect the
wiring as detailed below and on the wiring diagram label on the
inside of the control box cover.
WARNING: Your spa must be supplied by a ground fault circuit
interrupter - residual current device (RCD) - with a tripping rating not
exceeding 30 mA in an electrical subpanel.
Removing or bypassing any GFCI breaker will result in an unsafe spa
and will void the spa's warranty.
IMPORTANT: Should you ever find the need to move or relocate your
spa, it is essential that you understand and apply these installation
requirements. Your spa has been carefully engineered to provide
maximum safety against electric shock. Remember, connecting the spa
to an improperly wired circuit will negate many of its safety features.
IMPORTANT: Service Technician must reconfigure spa using the soft
jumpers to allow spa heater to run concurrent with jet pump if a
second 16 amp breaker is installed.
NOTE: Long wiring runs may require larger-gauge wire than
stated.
4.0 mm²
2.1 mm²
4.0 mm²
2.1 mm²
4.0 mm²
2.1 mm²
Page 28