  • Page 1 Owner’s Manual Owner’s Manual...
  • Page 2 Watkins ® Manufacturing Corporation congratulates you on your decision to enjoy the finest spa available... Welcome to the growing family of Hot Spring ® spa owners. Owner’s Manual his Owner’s Manual will acquaint you with the operation and general maintenance of your new spa. We suggest that you take some time to carefully review all seven sections.
  • Page 3: Table Of Contents

    Main Control Panels..............34 Control Panels ................34 SPA SPECIFICATIONS ..........4 Indicator Lights................34 CONTROLS AND EQUIPMENT ......5 Locking Features ................34 ® LANDMARK (Model S) ..............5 Main Control Panel Buttons and Display ........35 ® GRANDEE (Model G) ..............6 Water Care ..................36 ™ VANGUARD (Model V) ..............7...
  • Page 4: Safety Information

    SAFETY INFORMATION IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS AVOIDING THE RISK TO CHILDREN DANGER: • RISK OF CHILD DROWNING. Extreme caution must be exercised to prevent unauthorized access by children. To avoid accidents, ensure that children cannot use a spa unless they are supervised at all times. WARNING: •...
  • Page 5: Unclean Water

    • Your spa uses ground fault circuit interrupters in the electrical subpanel. Before each use of the spa and with the unit operating, push the TEST button on each breaker. The switch should click over to the “Trip” position. Wait 30 seconds and reset each GFCI breaker by switching it completely off and then completely on.
  • Page 6: Important Spa Instructions

    AVOIDING THE RISK OF HYPERTHERMIA Prolonged immersion in hot water can result in HYPERTHERMIA, a dangerous condition which occurs when the internal temperature of the body reaches a level above normal (98.6°F). The symptoms of hyperthermia include unawareness of impending hazard, failure to perceive heat, failure to recognize the need to exit the spa, physical inability to exit the spa, fetal damage in pregnant women, and unconsciousness resulting in a danger of drowning.
  • Page 7: Spa Specifications

    SPA SPECIFICATIONS 7'7" ® 38" 6,000 6,195 230 volt, 50 amp Landmark square gallons lbs. lbs. lbs. per Single phase GFCI 8'4" (Model S) protected circuit .96 m feet square 1,987 2,810 2.31m foot litres 2.54m 7'7" ® 38" 6,000...
  • Page 8: Controls And Equipment

    Landmark ® Model S OVERHEAD VIEW ® A. SmartJet system lever ® B. Moto-Massage jet Comfort ® Control system lever ® C. JetStream jet Comfort Control system lever ® D. Precision jets Comfort Control system lever ® E. DreamJet Comfort Control system lever F.
  • Page 9: Grandee

    Grandee ® Model G OVERHEAD VIEW ® A. SmartJet system lever ® B. Moto-Massage jet Comfort ® Control system lever ® C. Precision jets Comfort Control system lever ® D. JetStream jet Comfort Control system lever E. Pillow F. Hydromassage jet with directional nozzle G.
  • Page 10: Vanguard ™ (Model V)

    Vanguard ™ Model V OVERHEAD VIEW ® A. SmartJet system lever ® B. Moto-Massage jet Comfort ® Control system lever ® C. Precision jets Comfort Control system lever D. Pillow E. Hydromassage jet with directional nozzle F. Hydromassage jet with rotary nozzle G.
  • Page 11: Sovereign

    Sovereign ® Limited Edition Model ILE OVERHEAD VIEW ® A. SmartJet system lever ® B. Moto-Massage jet Comfort ® Control system lever ® C. Precision jets Comfort Control system lever D. Pillow E. Hydromassage jet with directional nozzle F. Hydromassage jet with rotary nozzle G.
  • Page 12: Sovereign ® (Model I)

    Sovereign ® Model I OVERHEAD VIEW ® A. SmartJet system lever ® B. Moto-Massage jet Comfort ® Control system lever ® C. Precision jets Comfort ® Control system lever D. Pillow E. Hydromassage jet with directional nozzle F. Hydromassage jet with rotary nozzle G.
  • Page 13: Prodigy ® (Model H)

    Prodigy ® Model H OVERHEAD VIEW ® A. SmartJet system lever ® B. JetStream jet Comfort ® Control system lever ® C. Precision jets Comfort ® Control system lever D. Hydromassage jet with directional nozzle E. Hydromassage jet with rotary nozzle F.
  • Page 14: Jetsetter ® (Model J)

    Jetsetter ® Model J OVERHEAD VIEW ® A. SmartJet system lever ® B. JetStream jet Comfort ® Control system lever ® C. Moto-Massage jet Comfort Control system lever ® D. Precision jets Comfort Control system lever E. Pillow F. Hydromassage jet with directional nozzle G.
  • Page 15: Installation Instructions

    INSTALLATION INSTRUCTIONS Warning! Warning! SITE PREPARATION ou probably have a spot picked out for your new spa, whether it’s indoors or outdoors, on a patio or on a Watkins Manufacturing deck. Just make sure you check the following: Corporation recommends •...
  • Page 16: Spa Leveling Instructions

    ® ® NOTE: Due to the large size of the Landmark and Grandee spas, Watkins Manufacturing Corporation requires that these spas be installed on a level 4”- (10.1 cm) thick concrete pad and NOT shimmed in any manner.
  • Page 17 ™ Vanguard (Model V) Leveling Points NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. • 15 leveling points (place shims approx. 18” in from edge, then center middle shims). Page 14 Spa Leveling Instructions...
  • Page 18 ® Sovereign (Model I & ILE) Leveling Points NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. • 15 leveling points (place shims approx. 18” in from edge, then center middle shims). Page 15 Spa Leveling Instructions...
  • Page 19 ® Prodigy (Model H) Leveling Points NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. • 10 leveling points (place shims approx. 15” in from edge, then center middle shims). Page 16 Spa Leveling Instructions...
  • Page 20 ® Jetsetter (Model J) Leveling Points NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. • 10 leveling points (place shims approx. 15” in from edge, then center middle shims). Page 17 Spa Leveling Instructions...
  • Page 21: Electrical Requirements And Precautions

    Troubleshooting section to identify and correct the cause. The power indicator will stop blinking once the problem has been corrected. 230 VOLT PERMANENTLY CONNECTED MODELS ™ • Landmark ® (Model S) • Vanguard (Model V) • Grandee ®...
  • Page 22 2. Wait 30 seconds, then push the breaker switch to the OFF (down) position (to ensure that it has completely disengaged), then push the breaker switch to the ON (up) position. If you don’t wait 30 seconds, the spa’s power indicator may continue to blink – try again. Landmark ®...
  • Page 23: 230 Volt Convertible Models

    115-230 VOLT CONVERTIBLE MODELS • Sovereign (Model I) ® • Prodigy ® (Model H) • Jetsetter ® (Model J) 230 VOLT CONVERSION INSTRUCTIONS Refer to the following instructions to convert a 115 volt spa to a 230 volt spa. NOTE: Converting the spa to 230 volt operation should only be done by an authorized service agent or a qualified electrician.
  • Page 24 4. Connect the #10 AWG, BLUE wire from the subpanel 30 amp breaker, terminal L1 to TB-1, terminal 1. 5. Connect the #10 AWG, RED wire from the subpanel 30 amp breaker, terminal L2 to TB-1, terminal 3. 6. Connect the #10 AWG, GREEN wire from the subpanel ground bar to TB-1 system ground terminal. 7.
  • Page 25: Volt Operation

    ELECTRICAL REQUIREMENTS FOR 115 VOLT OPERATION The spa must be connected to a dedicated 115 volt, 20 amp, GFCI protected, grounded circuit. The term “dedicated” means the electrical circuit is not being used or shared for any other electrical items (patio lights, appliances, garage circuits, etc.). If the spa is connected to a non-dedicated circuit, overloading will result in “nuisance tripping”...
  • Page 26: Operating Instructions

    230 volt permanently connected, and 115 / 230 volt convertible models. ® ® ™ ® The largest spa models, the Landmark , Grandee , Vanguard , and Sovereign Limited Edition are available only as 230 volt permanently connected models (these spas can not be converted to 115 volt systems), and utilize a continuous heating system.
  • Page 27: Start-Up And Refill Procedures

    3. The jet pump, heating system, and all internal plumbing will achieve a partial prime as the spa is filled. To check the operation of the jet ® ® system and to purge any remaining air from the heating system, push the JETS button (for the Landmark and Grandee , push both JETS 1 and JETS 2 buttons) to make the jet pump run on high speed for one minute.
  • Page 28: Smartjet ® System

    ™ ® ® ® ® On the Vanguard , Grandee , Landmark , Sovereign Limited Edition, and Jetsetter , each ® ® SmartJet lever controls two jet systems. To access a jet system, simply turn the SmartJet 9 o’clock...
  • Page 29: Soothing Seven ® Jet

    JETS ® ® ® ® ™ ® Precision jets are located above Moto-Massage jets and in groups of various sizes in the Landmark , Grandee , Vanguard , Sovereign Limited ® ® Edition, Sovereign , and Prodigy models. They are designed to perform a soft, soothing massage on your back and shoulders. Adjust the pressure ®...
  • Page 30: Jet System Menus

    Landmark (Model S) Jet System Menu Landmark (Model S) Jet System Menu ® ® Left Jet Pump–Jet System 1 Right Jet Pump–Jet System 1 ® ® Left SmartJet lever in the 3 o’clock position Right SmartJet lever in the 3 o’clock position ™...
  • Page 31: Grandee (Model G)

    Grandee (Model G) Jet System Menu Grandee (Model G) Jet System Menu ® ® Left Jet Pump–Jet System 1 Right Jet Pump–Jet System 1 ® ® Left SmartJet lever in the 3 o’clock position Right SmartJet lever in the 3 o’clock position ®...
  • Page 32: Vanguard (Model V)

    Vanguard (Model V) Jet System Menu Vanguard (Model V) Jet System Menu ™ ™ Jet System 1 ® SmartJet lever in the 3 o’clock position ® • 1 Moto-Massage jet on left rear ® ® • 4 Precision jets above left Moto-Massage ®...
  • Page 33 Sovereign Limited Edition (Model ILE) Jet System Menu Sovereign Limited Edition (Model ILE) Jet System Menu ® ® Jet System 1 ® SmartJet lever in the 3 o’clock position ® • 1 Moto-Massage jet on right rear ® ® • 4 Precision jets above Moto-Massage ®...
  • Page 34: Sovereign ® Limited Edition (Model Ile)

    Sovereign (Model I) Jet System Menu Sovereign (Model I) Jet System Menu ® ® Jet System 2 Jet System 1 ® ® SmartJet lever in the 6 o’clock position SmartJet lever in the 3 o’clock position ® ® • 1 Moto-Massage jet on left rear •...
  • Page 35: Prodigy ® (Model H)

    Prodigy (Model H) Jet System Menu Prodigy (Model H) Jet System Menu ® ® Jet System 1 Jet System 2 ® ® SmartJet lever in the 3 o’clock position SmartJet lever in the 6 o’clock position ® • 10 Precision jets on right rear •...
  • Page 36: Sovereign

    • 1 directional hydromassage jet on back wall hydromassage, 1 dual port rotary) ® • 1 JetStream jet on front left Control Panels Vanguard ™ Sovereign ® Limited Edition Sovereign ® Prodigy ® Jetsetter ® Landmark ® Grandee ® Page 33 Control Panels...
  • Page 37: Main Control Panels

    At night, the main control panel and display are illuminated by a soft light from the top of the panel. ® ® ™ ® ® ® The auxiliary control panel (Landmark , Grandee , Vanguard , Sovereign Limited Edition, Sovereign , Prodigy ) is conveniently located so that a user inside the spa can operate the light or the jets.
  • Page 38: Main Control Panel Buttons And Display

    ® ® The JETS button (all models) / JETS 1 (Landmark and Grandee models only) activates the jet pump. When the JETS or JETS 1 button is pressed, the jets symbol will illuminate on the control panel display. The symbol will remain lit until the button is pressed to turn off the jet pump, or after two hours of continuous operation when the pump is automatically shut off by the control system.
  • Page 39: Water Care

    AUXILIARY CONTROL PANEL ® ® ™ ® ® The auxiliary control panel, conveniently located in the spa seating area (Landmark , Grandee , Vanguard , Sovereign , and Prodigy models), allows the user to activate the jets and light from inside the spa.
  • Page 40: Volt Gfci

    LIGHT CONTROL See Main Control Panel’s Light Control section. 115 VOLT GFCI The Ground Fault Circuit Interrupter is a safety device that is designed to detect as little as 5 milliamps (±1mA) of electrical current leakage to ground. Watkins Manufacturing Corporation recommends that the GFCI be tested prior to each use to ensure it is functioning correctly.
  • Page 41: Spa Care And Maintenance

    SPA CARE AND MAINTENANCE GENERAL INFORMATION ® our Hot Spring spa is manufactured from the highest quality, most durable materials available. Even so, the spa care and maintenance program you develop will ultimately determine how long your spa, and its individual components, will last. Regular maintenance and following the advice in this section will help you to protect your investment.
  • Page 42: Filter Cartridges Removal And Cleaning

    Edition only). Stains and dirt generally will not adhere to your spa’s surface. A soft rag or a nylon scrubber should easily remove most dirt. Most ® ™ household chemicals are harmful to your spa’s shell. Watkins Manufacturing Corp. recommends HotSpring FreshWater Spa Shine; the only ®...
  • Page 43: Care Of The Spa Cover

    ® EVERWOOD SPA CABINET ® Hot Spring spas include an Everwood spa cabinet. Everwood consists of a rigid polymer that combines the durability of plastic with the beauty of redwood. Everwood won’t crack, peel, blister or delaminate even after prolonged exposure to the elements. ®...
  • Page 44: Vacation Care Instructions

    water) and place the other along the side of the cover, just above the skirt. Gently push (do not lift) with both hands towards the opposite rear corner of the cover (diagonally). As the cover opens, the gas springs will allow the cover to come to a gentle stop. ®...
  • Page 45: Prevention Of Freezing

    PREVENTION OF FREEZING ® Your Hot Spring spa has been designed and engineered for year-round use in any climate. In some areas, extremely cold temperatures (below 10°F) combined with strong wind, may cause partial freezing of the jet pump, even though the water inside the spa remains at the selected temperature.
  • Page 46: Water Quality And Maintenance

    c) Place the shop vac hose over the secondary “freeze” drain outlet and allow it to draw any remaining water from the spa’s bleedlines (approximately 3 to 5 minutes). 9. Thoroughly dry the spa shell with a clean towel. 10. Leave the main drain valve open approximately 1/2 turn and leave the caps off of both outlets during the winter months. 11.
  • Page 47: Hot Spring ® Spa Water Maintenance Program

    • Accurately measure the exact quantities specified, never more. Do not overdose your spa. • Handle all containers with care. Store in a cool, dry, well ventilated place. • Always keep chemical containers closed when not in use. Replace caps on their proper containers. •...
  • Page 48 BALANCING THE CALCIUM HARDNESS (CH) A. The recommended Calcium Hardness (CH) level for your spa is 150-200 ppm. B. Calcium Hardness is a measure of the total amount of dissolved calcium in the water. Calcium helps control the corrosive nature of the spa’s water.
  • Page 49: Everfresh ® Water Care System

    MAINTAINING THE SANITIZER LEVEL A. Sanitizer is extremely important for killing algae, bacteria and viruses, and preventing unwanted organisms from growing in the spa. At the same time, you don’t want too high a sanitizer level, or it can irritate your skin, lungs, and eyes. B.
  • Page 50: Hot Spring Water Treatment Guide

    Add one-half (1/2) teaspoon of chlorine per Add one (1) tablespoon of monopersulfate 250 gallons (MPS)* per 250 gallons each use ® Landmark (Model S) 1 teaspoon Landmark (Model S) 2 tablespoons ® (Test before adding Grandee (Model G) 1 teaspoon Grandee (Model G) 2 tablespoons any chemicals;...
  • Page 51: Freshwater Ag+® Silver Ion Purifier Replacement ......................48

    FRESHWATER SILVER ION PURIFIER REPLACEMENT ® INSTRUCTIONS When replacing the FreshWater silver ion purifier (every four months), it is highly recommended that the spa be drained and refilled at the same Ag + time. After refilling the spa with water, balance the Total Alkalinity (TA), Calcium Hardness (CH) and pH to the recommended levels. Shock the spa by adding sanitizer, either MPS or sodium dichlor.
  • Page 52: Chlorine (Sodium Dichlor)

    CHLORINE (SODIUM DICHLOR) A. Sanitizing chemicals, such as chlorine, are oxidants that kill bacteria and viruses in the water. The Free Available Chlorine (FAC) is a measure of the amount of unused chlorine available to sanitize the spa. The recommended FAC for your spa water is 3.0-5.0 ppm. B.
  • Page 53: Ozone

    NOTE: Well water may contain high concentrations of minerals. The use of a low water volume, extra-fine pore water filter (in-line pre-filter such as ® the FreshStart pre-filter) will help to remove many of the larger particles during the filling of the spa. In-line pre-filters can be purchased at 10,000 ®...
  • Page 54: Common Water Chemistry Questions

    8. Run the spa until all 16 ounces of the vinegar are gone. This should allow an ample flow of vinegar to be run through the injector and clear the blockage. 9. Disconnect power to the spa. 10. Remove the empty cup or bucket. 11.
  • Page 55: Water Terminology

    Answer: While over-exposure to any chemical can be unhealthful, many low levels of chemicals are effective and beneficial. In the case of spa ® water, the chemicals recommended in the Hot Spring water maintenance program are needed to protect the user from water-borne pathogens ®...
  • Page 56: Service Information

    SERVICE INFORMATION GENERAL INFORMATION ® our Hot Spring spa has been designed to provide years of trouble-free use. As with any appliance, problems may occasionally occur that require the expertise of a qualified service person. Though such simple repairs as resetting a GFCI switch or breaker, resetting a high limit thermostat or replacing a light bulb may not require a service call, they may indicate that a more serious condition exists.
  • Page 57: Miscellaneous Service Information

    the spa) and verify that the CD tube and its transformer are energized (a slight buzz will be emitted from the ozone generator housing). If a slight buzz or hum is not audible, verify that the generator is completely plugged into the spa’s control box. If the unit is plugged in and power is connected to the spa, then the fuse (for the ozone generator) should be checked.
  • Page 58: Troubleshooting Guides

    TROUBLESHOOTING ® Should you experience any problem whatsoever, do not hesitate to contact your authorized Hot Spring dealer. Here are some tips to help you to diagnose and rectify some more common sources of trouble yourself, if you choose to do so. GENERAL OPERATION TROUBLESHOOTING GUIDE Problem Probable causes...
  • Page 59: Spa Care And Maintenance Record

    SPA CARE AND MAINTENANCE RECORD Date Date Page 56 Care and Maintenance Record...
  • Page 60 JETSETTER (MODEL JC) 12/01 ©2001 Watkins Manufacturing Corporation. Hot Spring, Built for a lifetime of relaxation, Endurol, Moto-Massage, Landmark, Grandee, Vanguard, Sovereign, Prodigy, Jetsetter, Jet-Cluster, SmartJet, Comfort Control, No-Fault, IQ 2020, Wavemaster, Silent Flo 5000, DreamJet, Soothing Seven, JetStream, Precision, Everwood, CoverCradle, UpRite, GlideRite, EverFresh, FreshStart, FreshWater, FreshWater , HydroPulse and The Home Relaxation Specialists are trademarks of Watkins Manufacturing Corporation.

This manual is also suitable for:

GrandeeJetsetterVanguardSovereignProdigy

Table of Contents