HotSpring LimeLight GLEAM Owner's Manual

HotSpring LimeLight GLEAM Owner's Manual

Hide thumbs Also See for LimeLight GLEAM:
Table of Contents

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for HotSpring LimeLight GLEAM

  • Page 2 Prior to registering, you will need the serial number that is located within the equipment compartment of your HOT SPRING spa. To register please go to http://www.hotspring.com/hot-tub-owners/hot-tub-product-warranty-registration or simply scan the QR code below: FOR YOUR RECORDS...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS TABLE OF CONTENTS SAFETY INFORMATION FILTER SYSTEM ..............25 FILTER CARTRIDGES IMPORTANT SAFETY INSTRUCTIONS ......1 REMOVAL & CLEANING .............25 IMPORTANT CARE OF THE SPA PILLOWS ..........25 SPA INSTRUCTIONS ............. 3 CARE OF THE EXTERIOR ..........26 GETTING STARTED CARE OF THE SPA COVER ..........26 SPA FEATURES..............
  • Page 4: Safety Information

    • Do not operate the main audio/video button controls on any external afety nformatIon media devices such as a CD or DVD player while inside in the spa. Operation of integrated audio/video equipment through the spa control IMPORTANT SAFETY panel or wireless remote is permitted and acceptable. •...
  • Page 5 DON'T: UNCLEAN WATER • Use the spa with the equipment compartment door removed. • Place electrical appliances within 1.5 m (5 feet) of the spa. • Keep the water clean and sanitized with correct chemical care. The • Use an extension cord to connect the spa to its power source. The recommended levels for your HOT SPRING spa are: cord may not be properly grounded and the connection is a shock Free Available Chlorine:...
  • Page 6: Important Spa Instructions

    • Test the water with your hand before entering the spa to be sure it’s not able to resolve the problem, contact your authorized HOT SPRING comfortable. dealer. Many problems can easily be diagnosed over the telephone by an Authorized Service Technician. SAFETY SIGN SPA SHELL Your HOT SPRING spa has an acrylic shell.
  • Page 7: Getting Started

    ettInG tarted SPA FEATURES 1) Standard LCD Contol Panel. The control panel is accessible from inside or outside the spa and is designed for ease of use. 2 ) The Diverter lets you divert water to different combinations of jets simply by turning the lever. 3) The Air Control lever lets you dial in the ideal amount of air for both the Precision ™...
  • Page 8: Quick Start-Up Instructions

    MOTO-MASSAGE DX JET (GLEAM ONLY) rotate face body in either direction until you feel the body align with the fitting, then press firmly on the face body. Once seated, push The MOTO-MASSAGE DX jet automatically travels up and down in a and rotate the face clockwise using a little extra force to overcome sweeping motion, simulating the natural stroking effects of a manual the locking position.
  • Page 9 GLEAM Model: • Push the JETS hard button. • Know which water treatment system you will be using and make sure • Push the JETS MAX soft button to turn on all the jets and run for you have necessary chemicals available. Read all of the instructions one minute.
  • Page 10: Equipment Compartment

    Activate the clean cycle again to circulate the spa water for another 9. RECHECK the Total Alkalinity (TA) at 80 ppm, Calcium Hardness ten-minute period. (CH) at 100 ppm (if using ACE system 50 ppm), then spa water pH at between 7.2 and 7.8. using a FRESHWATER 5-way test strip. 8.
  • Page 11: Water Quality And Maintenance

    This type of damage is considered chemical abuse and CLEAN SCREEN Prefilter EverFresh System ™ is not covered under the terms of the limited warranty. *For more information visit www.hotspring.com/save-water Water Quality and Maintenance Page 8...
  • Page 12: Fundamentals Of Water Maintenance

    FUNDAMENTALS OF cloud water. The recommended pH reading is between 7.2 - 7.8. To lower the pH level, use FRESHWATER pH/Alkalinity Down (sodium WATER MAINTENANCE bisulfate). To raise the pH level, use FRESHWATER pH/Alkalinity Up (sodium carbonate). • Testing: Test the water weekly or each time the spa is used with convenient FRESHWATER 5-way test strips or more accurate liquid/ •...
  • Page 13: The Hot Spring Spa Water Maintenance Program

    ACE SALT WATER SANITIZING SYSTEM IMPORTANT: DO NOT use tri-chlor chlorine, bromo-chloro-dimethyl- hydantoin (BCDMH), or any type of compressed bromine or chlorine, (OPTIONAL) acid or any type of sanitizer which is not recommended by Watkins Manufacturing Corporation. The ACE Salt Water Sanitizing System converts water and sodium chloride salt into chlorine sanitizer.
  • Page 14: Vacation Water Care Instructions

    OZONE MAINTENANCE LONG TIME PERIODS (5-14 DAYS): Reduced or no ozone bubbles coming from heater return (clogged Prior to leaving: ozone injector) or no ozone, clean the injector: 1. At least one day before you leave, set the temperature to its lowest 1.
  • Page 15: Water Terminology

    Eventually the soap build-up in the water will be concentrated, resulting MPS: Monopersulfate is the non-chlorine oxidizer used with the in an unclean feeling on the bather’s skin, which is impossible to remedy. FRESHWATER Ag+ silver ion purification system. Not a sanitizer. When this occurs, it’s time to drain and refill the spa.
  • Page 16: Standard Lcd Control Panel

    lcd c INDICATOR ICONS tandard ontrol anel The indicator icons can only be seen on the Home Screen. They are The control panel provides a quick visual check of the spa’s status and visible whenever the icons function is active. allows the user to set the temperature, activate the jets &...
  • Page 17: Home Screen

    HOME SCREEN To increase the set temperature of the spa water: • Press the soft button next to ▲. The temperature displayed in the Each time the button is pressed, center of the Home screen is the the set temperature display will actual temperature of the spa water.
  • Page 18: Jets Control

    SPA LOCK BOLT When activated, the Spa Lock feature 1st press = jet pump on High 2nd press = jet pump OFF disables all functions on the control panel. It prevents others from tampering LIGHT CONTROL with the jets, lights and temperature settings on your spa.
  • Page 19: Language

    ACE WATER CARE (OPTIONAL) panel and will remain displayed for as long as the summer timer is on. The circulation pump and heater will automatically shut down for the same eight hours every day until the summer timer is deactivated. It is If your spa has the ACE WATER CARE system installed you can recommended to activate the summer timer in the morning so that the navigate to the ACE screen as follows:...
  • Page 20 TO PAUSE/PLAY (SONG) TO ADJUST BASS • Press the soft button next to • Press the soft button next to ▲ or ▼ PLAY/PAUSE (top right corner) to play or to change the Bass between -5 and pause music. • Press the Function:PLAY/PAUSE •...
  • Page 21: Jet Menu

    LIMELIGHT COLLECTION GLEAM (MODEL GLME) Jet Pump 1 - Jet System 1 Jet Pump 1 - Jet System 2 Diverter lever in the position Diverter lever in the position a) 6 Direct jets b) 10 Direct jets a) 2 Combination XL jets b) 6 Direct jets c) 1 Combination XL jet d) 4 Direct jets...
  • Page 22: Pulse (Model Plse)

    LIMELIGHT COLLECTION PULSE (MODEL PLSE) Jet Pump 1 a) 2 Combination XL jets b) 2 Direct jets c) 2 Combination jets d) 6 Direct jets e) 2 Combination jets f) 1 Water Feature (left wall) lever must be in ON position Jet Pump 2 - Jet System 1 Jet Pump 2 - Jet System 2...
  • Page 23: Pulse Dl (Model Plsde)

    LIMELIGHT COLLECTION PULSE DL (MODEL PLSDE) Jet Pump 1 a) 2 Combination jets b) 4 Direct jets c) 2 Combination XL jets d) 1 Combination XL jets e) 4 Direct Hydromassage jets f) 2 Direct Hydromassage jets g) 1 Water Feature (lever must be in ON position) Jet Pump 2 - Jet System 2 Jet Pump 2 - Jet System 1 Diverter lever in the...
  • Page 24: Flair (Model Flre)

    LIMELIGHT COLLECTION FLAIR (MODEL FLRE) Jet Pump 1 a) 2 Combination jets b) 2 Combination jets c) 4 Direct jets d) 1 Combination XL jet e) 1 Combination XL jet f) 1 Water Feature (right wall) lever must be in ON position Jet Pump 2 - Jet System 2 Jet Pump 2 - Jet System 1 Diverter lever in the...
  • Page 25: Bolt (Model Blte)

    LIMELIGHT COLLECTION BOLT (MODEL BLTE) Jet Pump a) 8 Direct jets b) 4 Direct jets c) 2 Combination jets d) 2 Combination jets e) 1 Combination XL jet Page 22 Jet Menus...
  • Page 26: Glow (Model Glwe)

    LIMELIGHT COLLECTION GLOW (MODEL GLWE) Jet Pump 1 a) 10 Direct jets b) 6 Direct jets jets c) 2 Combination jets d) 1 Water Feature (right wall) lever must be in ON position Jet Pump 2 a) 4 Direct jets b) 1 Combination XL jet c) 1 Combination XL jet d) 2 Direct jets...
  • Page 27: Winterizing Your Spa

    during these cold periods, as the heater will cycle more frequently. are and aIntenance As an additional precaution against partial freezing of some of the components, the equipment compartment can be insulated with an Your HOT SPRING spa is manufactured from the highest quality, most insulating kit (available from your local dealer).
  • Page 28: Filter System

    SECONDARY SUCTION SCREEN 8. Close the spa cover and fasten the cover tie downs. Cover the spa cover with two pieces of plywood to evenly distribute the weight of Located in the foot well of your spa are three secondary suction screens. snow and ice.
  • Page 29: Care Of The Exterior

    CARE OF THE EXTERIOR VINYL COVER The vinyl spa cover is an attractive, durable foam insulation product. SPA SHELL Monthly cleaning and conditioning are recommended to maintain its beauty. Your HOT SPRING spa has an acrylic shell. Stains and dirt generally will not adhere to your spa’s surface.
  • Page 30: Cover Lifter System

    COVER LIFTER SYSTEM HOW TO CLOSE THE COVER Clearance required behind cover when open: Standing along side the cover, place one hand on the upper corner of the cover and gently push forward in the direction of the spa. The ™...
  • Page 31: Electrical Requirements

    disconnect switch at least 3 mm separation between contacts must be lectrIcal eQuIrementS used for all electrical circuits to the spa. NOTE: The GLEAM will require an additional 16 amp breaker in order WIRING INSTRUCTIONS to operate the heater and jet pump 3 at the same time. Without the Your HOT SPRING spa has been carefully designed to give you maximum additional 16 amp breaker, the heater will NOT operate while jet pump safety against electric shock.
  • Page 32: Gleam - Wiring Instructions

    GLEAM - WIRING INSTRUCTIONS CONDUIT INSTALLATION INSTRUCTIONS 1. To connect the electrical service, first remove the screws from the ELECTRICAL REQUIREMENTS AND equipment compartment door. PRECAUTIONS 2. Locate the control box. Loosen the screws on the front of the control box. Remove the screws and the control box cover.Route Your spa has been carefully designed to give you maximum safety against the electrical service from the subpanel into the spa equipment electrical shock.
  • Page 33: Installation Instructions

    naturally increase with the spa installed. Water may get into woodwork nStallatIon nStructIonS and produce dry rot, mildew, or other problems. Check for airborne moisture’s effects on exposed wood, paper, etc. in the room. To SITE PREPARATION minimize these effects, it is best to provide plenty of ventilation to the spa area.
  • Page 34: Spa Leveling Instructions

    SPA LEVELING INSTRUCTIONS The following base support diagrams for the ENVOY, VANGUARD, ARIA, SOVEREIGN, TRIUMPH, PRODIGY & JETSETTER spas In order for your HOT SPRING spa to operate properly, and the internal indicate the recommended shimming points. plumbing to drain completely, the spa must be level. Notice: Though designed for outdoor installation, your HOT SPRING WARNING: Watkins Manufacturing Corporation recommends that a spa is not impervious to damage that may be caused by insects,...
  • Page 35: Ground Preparation

    INSTALLATION NOTES: The crane has a truck-mounted boom which can fit right in your driveway. It must be run by a licensed and insured operator. For a If you are purchasing a deck package or a gazebo with your spa, a solid charge, the crane operator will lift your spa over walls, buildings, or foundation becomes mandatory.
  • Page 36: Gleam (Model Glme)

    GLEAM (MODEL GLME) GLEAM Dimensions NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. Door Door Door (Front view) 95” ( 241.5 cm) Drain 20” (51 cm) Electrical Cutout 1 3/4" (4.5 cm) 49.5” (125.5 cm) 110"...
  • Page 37: Pulse/Dl (Model Plse/Plsde)

    PULSE/DL (MODEL PLSE/PLSDE) Dimensions PULSE NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. (Front view) Door Door Door 74.5” (189 cm) Drain 18.5” (47 cm) Electrical Cutout 1 3/4" (4.5 cm) 40.5” (103 cm) 89"...
  • Page 38: Flair (Model Flre)

    FLAIR (MODEL FLRE) Dimensions FLAIR NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. (Front view) Door Door Door 69.5” (176.5 cm) Drain 19” (48.5 cm) Electrical Cutout 1 3/4" (4.5 cm) 31” (78.5 cm) 84”...
  • Page 39: Bolt (Model Blte)

    BOLT (MODEL BLTE) Dimensions BOLT NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. (Front view) Door Door Door 65” (165 cm) Drain 18.5” (47 cm) Electrical Cutout 1 3/4" (4.5 cm) 34” (86.5 cm ) 80”...
  • Page 40: Glow (Model Glwe)

    GLOW (MODEL GLWE) Glow Dimensions NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. (Front view) Door Door Door 61.5” (156 cm) Drain 19” (48.5 cm) Electrical Cutout 1 3/4" (4.5 cm) 33” (84 cm) 76"...
  • Page 41: Service Information

    If the spa is not heating, the red and green lights are blinking, but ervIce nformatIon the pump and light are operating, then the pressure switch may be open. Opening of the pressure switch is normally a result of one or a GENERAL INFORMATION combination of these problems: A clogged filter cartridge...
  • Page 42: Acts Invalidating Warranty

    DISCLAIMERS • If the pump is shutting down due to excessive heat, make sure the equipment compartment has adequate ventilation. The air gap at the Watkins Manufacturing Corporation shall not be liable for loss of use bottom must not be blocked. Should your jet pump continue to shut off of the HOT SPRING spa or other incidental, consequential, special, after short periods of use, contact a qualified service technician.
  • Page 43: Troubleshooting

    TROUBLESHOOTING Should you experience any problem, do not hesitate to contact your authorized HOT SPRING dealer. Here are some tips to help you to diagnose and rectify some more common sources of trouble yourself, if you choose to do so. GENERAL OPERATION TROUBLESHOOTING GUIDE Problem Probable causes...
  • Page 44: Spa Specifications

    SPA SPECIFICATIONS Spa Model Footprint Height Effective Heater Water Filled Dead Electrical Requirements Dimension Filter (Watts) Capacity Weight Weight* Weight* Area 220 - 240 volt, GLEAM 2.79 m 97 cm 9.3 m 1,500 1,925 liters 575 kg 3,140 kg 575 kg/m 16 &...
  • Page 48 This manual contains installation, operating, maintenance and service information for the following 2017 HOT SPRING LIMELIGHT spa models: USA MODEL EFFECTIVE DATE GLEAM (MODEL GLME) 12/16 PULSE /DL (MODEL PLSE/PLSDE) 12/16 FLAIR (MODEL FLRE) 12/16 BOLT (MODEL BLTE) 12/16 GLOW (MODEL GLWE) 12/16 Watkins Manufacturing Corporation Vista, California...

Table of Contents