Prior to registering, you will need the serial number that is located within the equipment compartment of your HOT SPRING spa. To register please go to http://www.hotspring.com/hot-tub-owners/hot-tub-product-warranty-registration or simply scan the QR code below: FOR YOUR RECORDS...
TABLE OF CONTENTS TABLE OF CONTENTS SAFETY INFORMATION BEAM ™ (MODEL BMIIE) ............25 STROBE ™ (MODEL STRBE) ..........26 IMPORTANT SAFETY INSTRUCTIONS ......1 IMPORTANT SPA INSTRUCTIONS ........3 SPA CARE AND MAINTENANCE GETTING STARTED DRAIN & REFILL INSTRUCTIONS ........27 PREVENTION OF FREEZING ..........27 SPA FEATURES..............
• Do not operate the main audio/video button controls on any external afety nformatIon media devices such as a CD or DVD player while inside in the spa. Operation of integrated audio/video equipment through the spa control IMPORTANT SAFETY panel or wireless remote is permitted and acceptable. •...
Page 5
DON'T: UNCLEAN WATER • Use the spa with the equipment compartment door removed. • Place electrical appliances within 1.5 m (5') of the spa. • Keep the water clean and sanitized with correct chemical care. The • Use an extension cord to connect the spa to its power source. The recommended levels for your HOT SPRING spa are: cord may not be properly grounded and the connection is a shock Free Available Chlorine:...
SPA SHELL SAFETY SIGN Your HOT SPRING spa has an acrylic shell. Stains and dirt generally will not adhere to your spa’s surface. A soft rag should easily remove Each HOT SPRING spa is shipped with a SAFETY SIGN in the owner’s most dirt.
ettInG tarted SPA FEATURES 1) Standard LCD Contol Panel. The control panel is accessible from inside or outside the spa and is designed for ease of use. 2 ) The Diverter lets you divert water to different combinations of jets simply by turning the lever. 3) The Air Control lever lets you dial in the ideal amount of air for the Precision ®...
PRECISION JETS Status Indicator: A GREEN indicator is on when spa functions are working normally. A YELLOW indicator is on when a spa function Precision jets are small, producing a precisely narrow stream of requires attention. A RED indicator is on and flashing when there is an massaging action.
Page 9
START-UP 6. DURING THE SUPER-CHLORINATION PERIOD , rotate the DIVERTER lever(s) through both operating positions, letting the Your HOT SPRING spa has been thoroughly tested during the spa water circulate (with jets on) for equal periods of time. The HOT manufacturing process to ensure reliability and long-term customer SPRING spa's diverter levers are designed to operate different jets satisfaction.
ettInG tarted EQUIPMENT COMPARTMENT The illustration below is to be used as a reference only (your spa may look different). The equipment compartment is located behind the front panel of the spa below the control panel. EQUIPMENT COMPARTMENT 1. Wavemaster jet pump 5.
*For more information visit www.hotspring.com/save-water ater ualIty and CHEMICAL SAFETY aIntenance When using chemicals, read the labels carefully and follow directions precisely. Though chemicals protect you and your spa when used BASIC INFORMATION correctly, they can be hazardous in concentrated form. Always observe the following guidelines: It’s important to have clean water.
FUNDAMENTALS OF lower the pH level, use FRESHWATER pH/Alkalinity Down (sodium bisulfate). To raise the pH level, use FRESHWATER pH/Alkalinity WATER MAINTENANCE Up (sodium carbonate). • Testing: Test the water weekly or each time the spa is used with • Water Conditioners: Spa fill water varies from location to location and convenient FRESHWATER 5-way Test Strips or more accurate liquid/ user to user, therefore it is important to consult with your dealer for an tablet reagent test kit per instructions.
THE HOT SPRING SPA WATER FRESHWATER SALT SYSTEM (OPTIONAL) MAINTENANCE PROGRAM The Salt System converts water and sodium chloride salt into chlorine sanitizer. This is compatible with chlorine based systems and chemicals. Although the system is reduced maintenance, it is not automatic. It FILLING THE SPA WITH WATER is important that the user regularly tests and balances the water.
VANISHING ACT INSTRUCTIONS PULSE FLAIR PRISM FLASH BEAM STROBE Instructions for Use: Test the spa water for hardness after jets shut off, which will take After filling your hot tub, use a test strip to measure the around 6 hours. hardness level of the water.
OZONE MAINTENANCE LONG TIME PERIODS (5-14 DAYS): (OPTIONAL) Reduced or no ozone bubbles coming from heater return (clogged Prior to leaving: ozone injector) or no ozone, clean the injector: 1. At least one day before you leave, set the temperature to its lowest 1.
Eventually the soap build-up in the water will be concentrated, resulting Nitric Acid: The formulation of nitric acid, a highly corrosive chemical, in an unclean feeling on the bather’s skin, which is impossible to remedy. is a byproduct of the ozone generating process. Nitric acid is produced When this occurs, it’s time to drain and refill the spa.
lcd c INDICATOR ICONS tandard ontrol anel The indicator icons can only be seen on the Home Screen. They are The control panel provides a quick visual check of the spa’s status and visible whenever the icons function is active. allows the user to set the temperature, activate the jets and lights, lock READY Indicator: The READY indicator icon is displayed the temperature and/or spa functions.
HOME SCREEN screen will be displayed. This screen will automatically revert to the Home screen after 45 seconds of non-use. To increase the set temperature of the spa water: • Press the soft button next to ▲. Each time the button is pressed, the set temperature display will increase by .5 °C (1°F) If the button is held down, the set...
ENERGY SAVING MODE SETUP In the Setup screen you will be able This mode allows you to save energy to set the spa clock, see internal by shutting off the heater at two information about your s pa, change predetermine times of the day for up to °F or °C, change brightness of the to 6 hours on each setting.
SCHEDULE DAILY LIGHTS LANGUAGE In this screen you will be able to The Control panel screen can be viewed automatically turn the Exterior lights on in seven different languages. The and off at a preset time. To enter into the languages are English, French, German, Schedule Daily Lights screen: Dutch, Swedish, Norwegian, and...
SOAK TIMER • Press the soft button next to ▲to increase the Minutes or press the Soak Timer is a count down to let you soft button next to ▼to decrease know you have been in the tub for the Minutes. 15 minutes.
JETS CONTROL The Additional Exterior Lights screen allows you to access the Schedule Daily Lights screen (see page 17 for more information on how this works) The JETS hard button activates the jet In the Schedule Daily Lights screen you will be able to automatically pumps.
Page 23
TO ADJUST VOLUME TO ADJUST BASS • Press the soft button next to ▲ or ▼ • Press the soft button next to ▲ or ▼ to change the volume level. to change the Bass between -5 and • Press the Function:SET soft button to advance to the Play/Pause function •...
JET MENUS PRISM (MODEL PSME) Jet Pump 1 - Jet System 1 Jet Pump 1 - Jet System 2 Diverter lever in the position Diverter lever in the position 1 Waterfall (lever must be in ON position 1 XL Directional jets 4 Standard Dual Rotary jets 1 Standard Dual Rotary jets 6 Directional PRECISION jets...
JET MENUS PULSE (MODEL PLSE) Jet Pump 1 2 XL Directional jets 1 Water Feature (lever must be in ON position) 2 Directional PRECISION jets 2 Standard Single Rotary jets 2 Standard Directional jets 7 Directional PRECISION jets Jet Pump 2 - Jet System 1 Jet Pump 2 - Jet System 2 Diverter lever in the position...
Jet menuS FLAIR (MODEL FLRE) Jet Pump 1 a. 2 Standard Directional jets 2 Standard Dual Rotary jets 4 Directional PRECISION jets d. 3 Standard Directional jets 1 XL Directional jets 1 Water Feature (lever must be in ON position) Jet Pump 2 - Jet System 2 Jet Pump 2 - Jet System 1 Diverter lever in the...
Jet menuS FLASH (FSHE) Jet Pump 1 2 Standard Single Rotary jets 1 Water Feature (Lever must be in ON position) 4 Directional PRECISION jets 4 Directional PRECISION jets 2 Standard Directional jets 1 XL Directional jet Jet Pump 2 - Jet System 1 Jet Pump 2 - Jet System 2 Diverter lever in the position...
components, the equipment compartment can be insulated with an are and aIntenance insulating kit (available from your local dealer). This insulating kit will also help to maximize the spa’s energy efficiency. Your HOT SPRING spa is manufactured from the highest quality, most durable materials available.
SECONDARY SUCTION SCREEN 8. Close the spa cover and fasten the cover tie downs. Cover the spa cover with two pieces of plywood to evenly distribute the weight of Located in the foot well of your spa are three secondary suction screens. snow and ice.
CARE OF THE EXTERIOR CARE OF THE SPA COVER WARNING: The cover is a manual safety cover that meets or SPA SHELL exceeds all prevailing requirements of ASTM 1346-91 for spa safety covers when installed and used correctly as of the date of manufacture. Your HOT SPRING spa has an acrylic shell.
COVER LIFTER SYSTEM HOW TO CLOSE THE COVER Clearance required behind cover when open: Standing alongside the cover, place one hand on the upper corner of the cover and gently push forward in the direction of the spa. The ™ ™...
disconnect switch at least 3 mm separation between contacts must be lectrIcal eQuIrementS used for all electrical circuits to the spa. Mount the subpanel according to local codes, but not closer than 1.5 WIRING INSTRUCTIONS meters (5') away. Your HOT SPRING spa has been carefully designed to give you CONDUIT INSTALLATION INSTRUCTIONS maximum safety against electric shock.
PRISM - WIRING INSTRUCTIONS CONDUIT INSTALLATION INSTRUCTIONS 1. To connect the electrical service, first remove the screws from the ELECTRICAL REQUIREMENTS AND equipment compartment door. PRECAUTIONS 2. Locate the control box. Loosen the screws on the front of the control box. Remove the screws and the control box cover.Route Your spa has been carefully designed to give you maximum safety the electrical service from the subpanel into the spa equipment against electrical shock.
naturally increase with the spa installed. Water may get into woodwork nStallatIon nStructIonS and produce dry rot, mildew, or other problems. Check for airborne moisture’s effects on exposed wood, paper, etc. in the room. To SITE PREPARATION minimize these effects, it is best to provide plenty of ventilation to the spa area.
DELIVERY ACCESS The crane has a truck-mounted boom which can fit right in your driveway. It must be run by a licensed and insured operator. For a First, locate the dimensions of your spa on the following chart. The charge, the crane operator will lift your spa over walls, buildings, or dimensions shown are the measurements of the spa in the vertical any other obstruction and place it as close to the installation site as position, laid on its side.
PRISM (MODEL PSME) PRISM Dimensions NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. (Front view) DOOR 103.5" (263 CM) 3.5" (9 CM) Air Vents* Drain Air Vents* 16.0" (40.5 CM) Electrical Cutout 1.75" (4.5 CM) 45.35"...
PULSE (MODEL PLSE) Pulse Dimensions NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. (Front view) DOOR 82.5" (210 CM) 3.5" (9 CM) Air Vents* Drain Air Vent* 15.75" (40 CM) Electrical Cutout 32.25" (82 CM) 1.75"...
FLAIR (MODEL FLRE) Dimensions Flair NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. (Front view) DOOR 77" (195.5 CM) 3.5" (9 CM) Air Vents* Drain Air Vent* 21.0" (53.5 CM) Electrical Cutout 1.75" (4.5 CM) 42.0"...
FLASH (MODEL FSHE) Dimensions Flash NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. (Front view) DOOR 77" (195.5 CM) 3.5" (9 CM) Air Vents* Air Vents* Drain 16" (40.5 CM) Electrical Cutout 1.75" (4.5 CM) 38"...
the pump and light are operating, then the pressure switch may be ervIce nformatIon open. Opening of the pressure switch is normally a result of one or a combination of these problems: GENERAL INFORMATION A clogged filter cartridge Your HOT SPRING spa has been designed to provide years of trouble- Blockage within the system plumbing free use.
ACTS INVALIDATING WARRANTY DISCLAIMERS The limited warranty is void if the HOT SPRING spa has been WATKINS WELLNESS shall not be liable for loss of use of the HOT SPRING spa or other incidental, consequential, special, indirect, or improperly installed, subjected to alteration, misused, or abused, or if any repairs on the spa are attempted by anyone other than an punitive costs, expenses or damages, which may include but are not authorized representative of WATKINS WELLNESS.
TROUBLESHOOTING Should you experience any problem, do not hesitate to contact your authorized HOT SPRING dealer. Here are some tips to help you to diagnose and rectify some more common sources of trouble yourself, if you choose to do so. GENERAL OPERATION TROUBLESHOOTING GUIDE Problem Probable causes...
SPA SPECIFICATIONS Spa Model Footprint Height Effective Heater Water Filled Dead Electrical Requirements Dimension Filter (Watts) Capacity Weight Weight* Weight* Area 220 - 240 volt, PRISM 2.79 m 97 cm 14 m 1,500 1,990 liters 540 kg 3,085 kg 585 kg/m 16 &...
Page 52
This manual contains installation, operating, maintenance and service information for the following 2025 HOT SPRING LIMELIGHT spa models: MODELS EFFECTIVE DATE PRISM (MODEL PSME) 10/24 PULSE (MODEL PLSE) 10/24 FLAIR (MODEL FLRE) 10/24 FLASH (MODEL FSHE) 10/24 BEAM (MODELS BMIIE) 10/24 STROBE (MODELS STBE) 10/24...
Need help?
Do you have a question about the Limelight PRISM and is the answer not in the manual?
Questions and answers