Spsource; Timer Lsp-Generation - HP FlexFabric 5930 Series Command Reference Manual

Hide thumbs Also See for FlexFabric 5930 Series:
Table of Contents

Advertisement

Examples
# Set the minimum LSP transmit interval to 500 milliseconds on FortyGigE 1/0/1.
<Sysname> system-view
[Sysname] interface fortygige 1/0/1
[Sysname-FortyGigE1/0/1] spbm timer lsp 500

spsource

Use spsource to configure an SPSource ID.
Use undo spsource to restore the default.
Syntax
spsource spsource-id
undo spsource
Default
ISIS-SPB generates an SPSource ID automatically.
Views
SPBM view
Predefined user roles
network-admin
Parameters
spsource-id: Specifies an SPSource ID in the range of 1 to 1048575.
Usage guidelines
Each SPBM node has a multicast address for each SPB VSI. This multicast address consists of one
shortest path source identifier (SPSource ID) and one I-SID. The I-SID identifies an SPB VSI, and the
SPSource ID identifies the node as a multicast source in the SPB VSI.
The SPSource ID must be unique in the VSI.
Examples
# Set the SPSource ID to 100.
<Sysname> system-view
[Sysname] spbm
[Sysname-spbm] spsource 100

timer lsp-generation

Use timer lsp-generation to configure the LSP generation timer parameters.
Use undo timer lsp-generation to restore the default.
Syntax
timer lsp-generation maximum-interval [ minimum-interval [ incremental-interval ] ]
undo timer lsp-generation
Default
The maximum interval is 2 seconds.