MOCK FIREPLACE ENCLOSURE RECOMMENDATIONS
The enclosure can be fabricated using any standard building
materials, providing that spacer brackets are fitted to the
heater to provide adequate clearances to combustible
materials. (see Fig 5).
The area of the cavity must not exceed our dimensions as
shown in the diagram. (see Fig 1).
If the enclosure is larger than our dimensions allow, a
separate boxed section around the heater will need to be
constructed.
The heater must sit on a solid, sealed base and the
enclosure must be sealed from any draughts and be
insulated as necessary to eliminate low temperatures.
An enclosure constructed to an existing room with a solid
floor and ceiling, and any other enclosure must have the
same characteristics of being sealed from any draughts and
suitably insulated from low temperatures. Failure to adhere to
this requirement will result in unreliable operation or failure to
operate correctly and is not covered by our warranty
conditions.
550mm MAX
FIG 1.
Page 2.
2400mm MAX
300mm MAX
345 mm TO 610 mm
STUD
45 mm
246 mm
C.L. OF
HEATER
325 mm
CANTEBURY WITH
RECTANGULAR FLUE
ADAPTOR FITTED
COWL
FIT
3 SCREWS
SMALL DIA
SINGLE
END WITH
SKIN FLUE
SWAGE
FLUE
ADAPTER
TOP PLATE
FLUE SUPPORT
MEASURE DISTANCE FROM
FLOOR TO TOP OF HEATER
FLUE OUTLET PLUS 2 mm
MAKE SURE THERE IS ADEQUATE VENTILATION IN ROOM.
METHOD A
STUD
FLUE
FLUE OPENING
OPENING
GAS INLET
DETAIL
600 mm MIN
BETWEEN TOP OF
COWL AND NEAREST
PART OF ROOF
ROOF CLADDING
FLUE ADAPTER
MAINTAIN 25 mm
TOP PLATE
CLEARANCE BETWEEN
FLUE SUPPORT
FLUE AND WOODWORK
WALL CLADDING
HEADER
12 mm FROM
BOTTOM OF
ADJUSTMENT
WALL CLADDING
STRAP
TO TOP OF HEATER
75 mm MAIN
STUD WALL
FLUE COWL
APPROVED
TO AG604
FLUE CLAMP
FLASHING
100 mm DIA
FLUE PIPE
TWIN
SKIN FLUE
FIG 6.
Page 7.