OVERALL DIMENSIONS OF THE HEATER CABINET.
(SEE FIG 3 AND 4. )
(SEE FIG 3 AND 4. )
* WIDTH
* WIDTH
(INCLUDING SPACERS)
(INCLUDING SPACERS)
* DEPTH
(WHEN FLUE SPIGOT ENGAGED)
* HEIGHT
(INCLUDING SPACERS)
SUPPORT BRACKET
FLUE SPIGOT
735mm
FIG 3.
470mm
FIG 4.
WHEN FLUE
SPIGOT
ENGAGED
Page 4.
Page 4.
FITZROY
CANTERBURY
735 mm
735 mm
387
mm
342 mm
620 mm
620mm
CLEARANCE
FROM COMBUSTIBLES
25mm
FLUE SPIGOT
MTG BRKT
380mm
100mm
620 mm
FITMENT OF SPACER BRACKETS AND BLANKET.
1. Fit top and side brackets to heater cabinet on diagonal corners
as shown each side. (see Fig 5). Use existing screw positions.
2.
Position insulation blanket on heater top aligned with edges.
Secure with aluminium tape (see Fig 5).
When using twin skin flue (Method A):
3. Remove the flue outlet supplied with heater and replace with
flue outlet supplied with mock kit.
4. Fit rear spacer brackets to heater cabinet on diagonal corners
as shown (see Fig 5). Use existing screw positions.
SECURE INSULATION BLANKET TO TOP OF HEATER
USING ALUMINIUM TAPE
FIXING SCREWS
FIXING SCREWS
No8 x 3/8" SELF TAPPING
No8 x 3/8" SELF TAPPING
BLANKET
INSULATION
FLUE OUTLET
(HEATER SUPPLIED)
REAR BRACKETS
REAR BRACKETS
TOP & SIDE
TOP & SIDE
BRACKETS
BRACKETS
FIG 5.
FIG 5.