B1500A Upgrade Options and Contents

The B1500AU allows to upgrade the B1500A mainframe and/or installed modules. Upgrade and installation must be performed at the
service center. The serial number and the configured module information are needed to order the upgrade. In addition to the selected
upgrade options, a few mainframe components can be required to replace for the prerequisite of the upgrade. Contact Keysight for the
quotation of the upgrade including the service charge.
B1500A upgrade options
Model/Option
Description
B1500AU
Upgrade kit for B1500A
Module upgrade options (optional)
B1500AU-010
Addition of B1510A High power
source/monitor unit module
B1500AU-11B
Addition of B1511B Medium power
source/monitor unit module
B1500AU-141
Addition of B1514A Medium
current source/monitor unit 1ea w/
connection box
B1500AU-142
Addition of B1514A Medium
current source/monitor unit 1ea w/o
connection box
B1500AU-017
Addition of B1517A High resolution
source/monitor unit module
B1500AU-088
Addition of E5288A Atto sense
and switch unit (ASU. HRSMU is
required.)
B1500AU-089
Addition of E5288A Atto sense and
switch unit (B1511B MPSMU is
required.)
B1500AU-020
Addition of B1520A Multi frequency
capacitance measurement unit
module
B1500AU-025
Addition of B1525A High voltage
semiconductor pulse generator unit
module
B1500AU-030
Addition of B1530A Waveform
generator/fast measurement unit
module with two RSUs
WGFMU and RSU cable options (mandatory for B1500AU-030)
B1500AU-W01
0.6m/2.4m cable set between
WGFMU and RSU(2ea). Require
prober I/F with adapter
B1500AU-W02
3m Cable between WGFMU and RSU
(2ea)
B1500AU-W03
5m Cable between WGFMU and RSU
(2ea)
B1500AU-W04
0.6m/4.4m Cable set between
WGFMU and RSU(2ea). Require
prober I/F with adapter
B1500AU-W05
1.5m Cable between WGFMU and
RSU (2ea)
Contents
Qty
Additional Information
-
-
Various upgrade option can be ordered as the option of B1500AU.
HPSMU
1
HPSMU module. No cable is included. Order B1500AU-T01/T02 or
16494A triaxial cable if necessary.
MPSMU
1
MPSMU module. No cable is included. Order B1500AU-T01/T02 or
16494A triaxial cable if necessary.
MCSMU
1
MCSMU module. No cable is included. Order B1500AU-T01/T02 or
16494A triaxial cable if necessary.
N1255A
1
N1255A Connection box for B1514A MCSMU
MCSMU
1
MCSMU module. No cable is included. Order B1500AU-T01/T02 or
16494A triaxial cable if necessary.
HRSMU
1
HRSMU module. No cable is included. Order B1500AU-T01/T02 or
16494A triaxial cable if necessary.
ASU
1
Atto sense switch unit (E5288A ASU). ASU will be tied with HRSMU.
No cable is included. Order B1500AU-A01/A02 or 16493M.
ASU
1
Atto sense switch unit (E5288A ASU). ASU will be tied with
MPSMU. No cable is included. Order B1500AU-A01/A02 or
16493M.
MFCMU
1
MFCMU module. No cable is included. Order B1500AU-C01/C02 or
N1300A cable and accessories.
HV-SPGU
1
HV-SPGU module. No cable is included. Order B1500AU-S01/S02,
or 16493P SMA-BNC cable and 16493Q if necessary.
WGFMU
1
WGFMU module. No cable is included. Order B1500AU-W01, W02,
W03, W04 or W05 for WGFMU-RSU cable.
RSU
2
Remote-sense and switch unit (RSU)
RSU cable
2
0.6 m (2ea) and 2.4m (2ea) RSU cables
RSU cable
2
3 m RSU cable
RSU cable
2
5 m RSU cable
RSU cable
2
0.6 m (2ea) and 4.4m (2ea) RSU cables
RSU cable
2
1.5 m RSU cable