Work Area Safety - Genie ZX-135/70 with Jib-Extend Operator's Manual

Boom lift
Hide thumbs Also See for ZX-135/70 with Jib-Extend:
Table of Contents

Advertisement

Operator's Manual

Work Area Safety

Work Area Safety
Electrocution Hazards
This machine is not electrically insulated and will
not provide protection from contact with or
proximity to electrical current.
Line Voltage
0 to 50KV
50 to 200KV
200 to 350KV
350 to 500KV
500 to 750KV
750 to 1000KV
Allow for platform movement, electrical line sway or
sag, and beware of strong or gusty winds.
10
Obey all local and
governmental regulations
regarding required
clearance from electrical
power lines. At a
minimum, the required
clearance contained in the
chart below must be
followed.
Required Clearance
3.05 m
4.60 m
6.10 m
7.62 m
10.67 m
13.72 m
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for welding.
Tip-over Hazards
Occupants, equipment and materials shall not
exceed the maximum platform capacity.
Maximum platform capacity
Maximum occupants
The weight of options and accessories, such as
pipe cradles, panel cradles and welders, will
reduce the rated platform capacity and must be
subtracted from the platform capacity. See the
decals with the options and accessories.
If using accessories, read, understand and obey
the decals, instructions and manuals with the
accessory.
ZX-135/70
Third Edition • First Printing
Keep away from the
machine if it contacts
energized power lines.
Personnel on the ground
or in the platform must not
touch or operate the
machine until energized
power lines are shut off.
272 kg
Part No. 1272823GT
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents