Operator's Manual

Work Area Safety

Electrocution Hazards
Line Voltage
0 to 50KV
50KV to 200KV
200KV to 350KV
350KV to 500KV
500KV to 750KV
750KV to 1000KV
Allow for platform movement, electrical line sway
or sag and beware of strong or gusty winds.
Keep away from the machine if it contacts
energized power lines. Personnel on the ground or
in the platform must not touch or operate the
machine until energized power lines are shut off.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for welding.
8
This machine is not
electrically insulated and
will not provide protection
from contact with or
proximity to electrical
current.
Maintain safe distances
from electrical power lines
and apparatus in
accordance with applicable
governmental regulations
and the following chart.
Required Clearance
3.05 m
4.60 m
6.10 m
7.62 m
10.67 m
13.72 m
Tip-over Hazards
Occupants, equipment and materials must not
exceed the maximum platform capacity or the
maximum capacity of the platform extension.
Weight in trays is part of the total platform load.
Maximum capacity - GRC-12
Platform retracted
Work station tray (each)
Maximum occupants
GRC-12
First Edition • First Printing
227 kg
11 kg
Do not raise the platform
unless the machine is on a
firm, level surface.
Do not depend on the tilt
alarm as a level
indicator. The tilt alarm
sounds inside the battery
charger tray only when the
machine is on a severe
slope.
Part No. 133136
2