Work Area Safety

Electrocution Hazards
This machine is not electrically insulated and will
not provide protection from contact with or
proximity to electrical current.
Line Voltage
0 to 50KV
50 to 200KV
200 to 350KV
350 to 500KV
500 to 750KV
750 to 1000KV
Part No. 1262335
Obey all local and
governmental regulations
regarding required
clearance from electrical
power lines. At a
minimum, the required
clearance contained in the
chart below must be
followed.
Required Clearance
10 ft
3.05 m
15 ft
4.60 m
20 ft
6.10 m
25 ft
7.62 m
35 ft
10.67 m
45 ft
13.72 m
SX-150 • SX-180
Work Area Safety
Allow for platform movement, electrical line sway
or sag, and beware of strong or gusty winds.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for welding.
Tip-over Hazards
Occupants, equipment and materials shall not
exceed the maximum platform capacity for the
restricted or unrestricted range of motion.
Maximum platform capacity
Maximum occupants
The weight of options and accessories such as
pipe cradles and welders will reduce the rated
platform capacity, and must be subtracted from the
platform capacity. See the decals with the options
and accessories.
If using accessories, read, understand and obey
the decals, instructions and manuals with the
accessory.
Operator's Manual
Keep away from the
machine if it contacts
energized power lines.
Personnel on the ground
or in the platform must not
touch or operate the
machine until energized
power lines are shut off.
750 lbs
340 kg
2
13