Section 5: Slideout Systems
5.
Unplug the motor from the harness and remove the motor by lifting it up and out.
6.
Repeat steps 1-4 for the other side.
7.
Place a socket wrench with a 3-inch extension and a 5/8" deep well socket (Fig 12)
through the motor access opening and seat the socket onto the coupler (Fig 13). One
person alternating from side to side of the room can retract a 1500 lb. room with or
without a ramp.
NOTE: One person on each side of the room with a ratchet and
socket will expedite the process. Room moves ¼ inch for every 30 to
40 degree turn of the wrench.
8.
Secure the room in place by either:
Re-installing the motors (making sure the end of the retaining screw is re-hooked
to the motor spring clip (Fig 10A).
Torque the motor retaining screw to 40 inch/lbs. (Fig 10B) and the motor retainer
is fully engaged.
Use a travel lock, (a 2x4 cut to size), etc.
Refer to Fig 10A and 10B for proper seating of the motor.
9.
Have the slideout room serviced by an OEM authorized dealer as soon as possible. Do
not operate the room until service is complete as damage to the room may result.