Section 8: Plumbing System
Maintenance
Inspect your water heater monthly and have it serviced at least once a year by the
manufacturer's recommended service technician. Contact your RV dealer, the manufacturer,
or Customer Service.
Pressure - Temperature Relief Valve
Valve is not serviceable; if defective it must be replaced.
Tampering with valve will result in scalding injury. Do not place a plug
or reducing coupling on outlet part of valve. If you use a discharge line
allow complete drainage for both valve and line.
Tampering with valve will void the warranty.
THIS VALVE IS A SAFETY COMPONENT AND MUST NOT BE REMOVED
FOR ANY REASON OTHER THAN REPLACEMENT.
THE PRESSURE RELIEF VALVE SHOULD ONLY BE REPLACED BY A
QUALIFIED SERVICE TECHNICIAN.
AQUA GO COMFORT / AQUA GO COMFORT PLUS MODELS:
ECO MODE: The water heater is running in energy saving mode. Propane gas is used
to prevent freezing. The temperature in the water heater is kept automatically above
41°F (5°C). Water temperature coming out of the fixtures is approximately 120°F
(49°C). When the water heater is running in ECO MODE a yellow status LED (LED
3) will be lit in the middle of the rotary dial control switch inside the RV.
COMFORT MODE: The appliance is running in a mode that provides rapid
availability of hot water. Water temperature at the fixtures is 120° (49°C).
System is operating in Stand by heat, which keeps water temperature in the appliance
at 102°F (39°C). While running in COMFORT MODE the yellow status LED on the
rotary control dial (LED 3) will be lit.
When the power switch is OFF, the appliance is not running in any operating mode.
Yellow status LED (LED 3) on the rotary dial is not lit.
Draining the Aqua Go Water Heater:
The Aqua Go water heater does not have a conventional drain plug. Instead it includes a
drain "chute".