Functions
5.9 Standard machine projects
Additional information
For more information on multiple use IO systems, refer to section Multiple use IO systems
(Page 200).
For more information on the configuration control for IO systems, refer to section
Configuration control for IO systems (Page 209).
For more information on configuration control, refer to the system manual S7-1500,
ET 200MP (http://support.automation.siemens.com/WW/view/en/59191792).
5.9.1

Multiple use IO systems

5.9.1.1

What you should know about multiple use IO systems

Multiple use automation solutions
For a flexible reusable automation solution as is the case with series machines, the following
use cases are typical:
● The machine (and therefore also the PROFINET IO system) is used more than once by
the customers.
● The machine is used in different plants by various customers.
For this to be possible, the automation solution must meet the following requirements:
● A project (configuration and program) can be loaded on various machines of the same
type without changes.
● Only a few easy adaptations need to be performed locally to integrate the machine into
an existing network infrastructure.