Setup Recommendations For Optimizing Profinet - Siemens SIMATIC PROFINET Function Manual

With step 7 v14
Hide thumbs Also See for SIMATIC PROFINET:
Table of Contents

Advertisement

5.5.7

Setup recommendations for optimizing PROFINET

Optimizing PROFINET with RT
PROFINET provides you with high-performance communication on all levels.
The following figures shows an example of an optimized PROFINET topology.
Figure 5-50
When setting up your PN network topology, take care that the various automation
applications are distributed among separate network branches so that a sufficient bandwidth
reserve will be available for future expansions.
● If you integrate standard Ethernet devices into the network topology or use standard
Ethernet communication, take into account the network load caused by standard Ethernet
and adapt the network topology as appropriate (max. bandwidth 100 Mbps).
● For communication with higher-level networks with a high data volume, use the most
direct paths possible to the higher-level network infrastructure.
Also observe the Installation Guideline
guide/downloads/profinet-installation-guide/display/) of the PROFIBUS User Organization.
PROFINET with STEP 7 V14
Function Manual, 09/2016, A5E03444486-AG
Optimized PROFINET topology
(http://www.profibus.com/nc/download/installation-
Functions
5.5 Real-time communication
167

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents