Control unit
2
1
1
Control
3XVK XS ÀDS XSVWUHDP RI 86% FRQQHFWLRQ
IRU TXDOL¿HG SHUVRQQHO IRU VRIWZDUH
updates and for data logging)
:DOOPRXQWHG EUDFNHW RQO\ QHFHVVDU\
for wall-mounted installation)
Underside of control
1
2
1
RBE (RS 485)
1HWZRUN FDEOH FRQQHFWLRQ
3
LIN bus cable connection to the heat pump
4
not used
3.2 Accessories
The following accessories are available for the unit
through the manufacturer's local partner:
$GGLWLRQDO PDVNLQJ SODWH IRU WKH IURQW FRYHU
panel, if the control is mounted on the wall
'RPHVWLF KRW ZDWHU WDQN
8
Subject to change without notice | 83057000cUK – Translation into English of the original German operating manual | ait-deutschland GmbH
3
4
Room thermostat for switching the cooling
function (if included)
Dew point monitor for protecting a system with
FRROLQJ IXQFWLRQ DW ORZ ÀRZ WHPSHUDWXUHV
Expansion board for automatic changeover
between heating and cooling mode
Manual output control heating element (MLRH)
for limiting the output of the electric heating
element
³&RROLQJ SDFNDJH´ IRU UHWUR¿WWLQJ W\SH + XQLWV
with a cooling function
for units without cooling: Pump assemblies
IRU VHSDUDWH VWRUDJH WDQN LQWHJUDWLRQ KHDWLQJ
circuit)
+HDWLQJ FLUFXLW VDIHW\ SDFNDJH
+HDW VRXUFH FLUFXLW VDIHW\ SDFNDJH
3.3 Function
Liquid refrigerant is evaporated (evaporator), the
energy for this process is environmental heat and
comes from the "ground" heat source (collector,
borehole heat exchanger). The gaseous refrigerant
is compressed (compressor), this causes the
pressure to rise and therefore the temperature too.
The gaseous refrigerant with high temperature is
OLTXH¿HG FRQGHQVHU
Here the high temperature is discharged to the
heating water and is used in the heating circuit.
The liquid refrigerant with high pressure and high
temperature is expanded (expansion valve). The
pressure and temperature drop and the process
begins again.
Due to the integrated changeover valve and the
LQWHJUDWHG HQHUJ\ HI¿FLHQF\ FLUFXODWLRQ SXPS WKH
heated heating water can be used for charging the
domestic hot water or for heating the building. The
temperatures required and use are controlled by the
heat pump controller. Reheating, drying out screed
or increasing the domestic hot water temperature
can be carried out using the integrated electric
heating element, which is activated by the heat pump
controller as and when necessary.
$Q LQWHJUDWHG RYHUÀRZ YDOYH HQVXUHV WKDW WKH KHDW
pump does not switch to high-pressure fault if all
heating circuits are closed. The integrated vibration
isolators for the heating circuit and heat source
prevent structure-borne sound and vibrations from
EHLQJ WUDQVIHUUHG RQWR WKH ¿[HG SLSHV DQG WKHUHIRUH
into the building.