About this operating manual 1.3 Symbols and identification markings This operating manual is part of the unit. Identification of warnings ► Before working on or with the unit read the operating manual carefully and follow it for all Symbol Meaning activities at all times, especially the warnings and Safety-relevant information.
All instructional information in this operating manual is this operating manual can be found on the internet at solely directed at qualified, skilled personnel. any time and is kept up-to-date: Only qualified, skilled personnel is able to carry out ● Germany: www.alpha-innotec.de the work on the unit safety and correctly. Interference by unqualified personnel can cause life-threatening ● www.alpha-innotec.com injuries and damage to property.
Injury due to flammable liquids and potentially If a system is not planned, designed, started up and operated according to the given requirements, there is explosive atmospheres a risk that the following damage and faults will o ccur: Constituents of antifreeze mixtures, e.g. ethanol, ● Malfunctions and the failure of components, e.g. methanol, are highly flammable and form an explosive pumps, valves atmosphere: ●...
Module box – variant with cooling Control unit 1 Control panel 2 Push up flap upstream of USB connection (for qualified personnel for software updates and 1 Compressor for data logging) 2 Condenser 3 Wall-mounted bracket (only necessary for 3 Vibration isolator (4x) wall-mounted installation) 4 Lifting lug (4x) 5 Evaporator 6 Heat source circulation pump Underside of the control panel 7 Heat source filling and drain tap 8 Heat source filling and drain tap...
Network connection on the control ● Dew point monitor for protecting a system with cooling function at low flow temperatures (if The control can be connected to a computer or available) network via a network cable. The heating and heat ● Expansion board pump controller can then be controlled from the computer or from the network.
Delivery, storage, transport Notes on safe transport and installation The housing with the unit components and the module box are heavy ( “Technical data / Scope of supply”, from page 22). There is a risk of injuries or damage to property if the housing with the unit components IMPORTANT falls or overturns or if the module box falls.
Page 10
Dismantle housing panels for transport with Transport with a handcart handcart or carrying the unit NOTE Unit is unpacked ( “Unpacking”, page 9). ● If transporting with a handcart the module To avoid damage to the housing panels: box must be pushed in. Undo 2 screws at the bottom of the front panel. ●...
Installation and connection 5.4 Installation Installation room and space requirements 6.1 Dismantle the module box NOTE IMPORTANT Note and follow the local regulations and If the module box is tilted by more than 45°, standards regarding the installation room compressor oil runs into the cooling circuit. and space requirements.
Page 12
► Unit with 14 kW capacity and higher: NOTE ● Disconnect connector (①) at the front of the The hose connectors are not part of the electrical control cabinet scope of delivery with all KFE ball valves. ● Disconnect connector (②) at the bottom of Close shut-off valves to the heat source.
Page 13
Remove 3 clips on the hydraulic connections. 11. Remove the 2 side retaining screws. 12. To protect the floor and move the module box (③) Use spanner size SW 37 to unscrew the heating more easily: place boards (④) under it, e.g. from flow. the packaging material. 10. Disconnect the hydraulic connections; to do this, push the pipes apart as far as necessary.
6.3 Install the hydraulic connections 15. Pull out the module box completely and place it on the boards. IMPORTANT Damage to the copper pipes due to unacceptable loading! ► Secure all connections against twisting. The heat source system has been installed in ...
6.4 Connect the electrical cables Pull in the cables and conductors and make the connections IMPORTANT Strip the sheathing of all cables to the external Irreparable damage to the compressor due to loads before laying in the cable duct of the control wrong rotating field! box. ► Ensure that there is a clockwise rotating field for Dismantle the cover of the electrical control box. the compressor load infeed.
6.5 Installing the control panel NOTE The control can be inserted in a recess in the front panel of the unit or can be installed on 200 mm the wall. Insert the control in the unit and connect If required: Remove masking plate from the slot. To do this, dismantle the front panel (...
Feed in the cables from the wall (e.g. in-wall box) ► When selecting the antifreeze agent, it must be or from below. ensured that it is compatible with the following materials: Route the LIN bus cable from the top right-hand ●...
7.4 Flush and fill the heating and Flush the heat source system thoroughly. domestic hot water charging Mix antifreeze with water thoroughly with the required ratio, before adding to the heat source. circuit Check the concentration of the water-antifreeze mixture. Heating water quality Fill the heat source with the water-antifreeze mixture.
Insulate hydraulic connections Commissioning Insulate heating circuit and heat source according Relevant planning & design data of the system is to the local regulations. documented in full. Open shut-off devices. The competent energy supplier has been notified of operation of the heat pump system. Perform a pressure test and check for leaks. System is air-free. ...
10 Maintenance 11 Faults ► Read out the cause of the fault via the diagnostics NOTE program of the heating and heat pump controller. We recommend that you sign a maintenance ► Contact the local partner of the manufacturer or agreement with accredited...
12 Dismantling and disposal 12.1 Dismantling Unit is safely disconnected from the power supply and protected against being switched back on again. ► Collect all media safely. ► Separate components by their materials. 12.2 Disposal and Recycling ► Dispose of media harmful to the environment according to local regulations, e.g.
SW 42(H)(K)3 – SW 192H3 Dimensional drawings ↑ ↓ ↑ ↓ Keys: UK819447 Keys: UK819447 Pos. Pos. Name Name 4kW –12kW 4kW –12kW 14kW – 19kW 14kW – 19kW All dimensions in mm. All dimensions in mm. Heating water outlet (flow) Heating water outlet (flow) Ø28 *) Ø28 *)
Schutzvermerk ISO 16016 beachten Dimensional drawings Control unit Schutzvermerk ISO 16016 beachten All dimensions in mm. All dimensions in mm. Bohrschablone Wall-mounted bracket Blattformat: A4 hoch Maßstab Det. Maßstab Allgemein- Oberflächen toleranz Werkstoff Gewicht Datum Name Benennung Maßbild SW Erstellt 25.11.2014 Brueckner Gepr.
SW 42(H)(K)3 – SW 192H3 Installation plan 1 1000 > 1 Legende: DE819456a Keys: UK819456a Keys: UK819456a Version 1 All dimensions in mm. All dimensions in mm. Freiraum für funktionsnotwendiges Zubehör V1 V1 Version 1 Version 1 FS FS Free space for service purposes Free space for service purposes Freiraum für Servicezwecke Oberkante Fertigfussboden...
Installation plan 2 SW 42(H)(K)3 – SW 192H3 1000 > 1 Legende: DE819456a Keys: UK819456a Keys: UK819456a All dimensions in mm. All dimensions in mm. Version 2 Freiraum für funktionsnotwendiges Zubehör V2 V2 Version 2 Version 2 FS FS Free space for service purposes Free space for service purposes Freiraum für Servicezwecke Oberkante Fertigfussboden...
SW 42(H)(K)3 – SW 192H3 Installation plan 3 > 1 > 1 Keys: UK819456a Keys: UK819456a Legende: DE819456a All dimensions in mm. All dimensions in mm. 1000 Version 3 V3 V3 Version 3 Version 3 Freiraum für Servicezwecke Oberkante Fertigfussboden Finished floor level Finished floor level Alle Maße in mm.
Hydraulic integration (heating) SW 42H3 – SW 192H3 Subject to change without notice | 83056800fUK – Translation of the original operating manual | ait-deutschland GmbH...
SW 42K3 Hydraulic integration (cooling) 8390065, IBN XXX Subject to change without notice | 83056800fUK – Translation of the original operating manual | ait-deutschland GmbH...
Terminal diagram SW 42K3 1~N/PE/230V/50Hz 3~N/PE/400V/50Hz OUT 4 OUT 5 OUT 6 OUT 7 OUT 8 OUT 9 OUT 10 OUT 11 OUT 12 OUT 13 OUT 14 OUT 15 OUT 16 OUT 17 NTC 6 NTC 7 NTC 8 TRL ext.
Circuit diagram 1/3 SW 42K3 !!! KEINE ÜBERSETZUNG !!! Subject to change without notice | 83056800fUK – Translation of the original operating manual | ait-deutschland GmbH...
Page 45
SW 42K3 Circuit diagram 2/3 OUT1 OUT 14 OUT 13 braun / grün weiß / gelb PWM1 !!! KEINE ÜBERSETZUNG !!! Subject to change without notice | 83056800fUK – Translation of the original operating manual | ait-deutschland GmbH...
Page 46
Circuit diagram 3/3 SW 42K3 braun / blau weiß grün gelb rosa blau violett grau / rosa rot / blau weiß / grün weiß / blau grau / braun rosa / braun NTC13 NTC14 !!! KEINE ÜBERSETZUNG !!! Subject to change without notice | 83056800fUK – Translation of the original operating manual | ait-deutschland GmbH...
SW 42H3 – SW 82H3 Circuit diagram 1/3 Subject to change without notice | 83056800fUK – Translation of the original operating manual | ait-deutschland GmbH...
Page 48
Circuit diagram 2/3 SW 42H3 – SW 82H3 OUT1 white / yellow brown / green PWM1 PWM2 Subject to change without notice | 83056800fUK – Translation of the original operating manual | ait-deutschland GmbH...
Page 49
SW 42H3 – SW 82H3 Circuit diagram 3/3 blue NTC9 brown / blue white green yellow pink NTC13 NTC14 white / blue grey / brown pink / brown violet grey / pink Black red / blue white / green Orange Yellow /2.D6...
Circuit diagram 1/3 SW 102H3 – SW 122H3 Subject to change without notice | 83056800fUK – Translation of the original operating manual | ait-deutschland GmbH...
Page 51
SW 102H3 – SW 122H3 Circuit diagram 2/3 OUT1 white / yellow brown / green PWM1 PWM2 Subject to change without notice | 83056800fUK – Translation of the original operating manual | ait-deutschland GmbH...
Page 52
Circuit diagram 3/3 SW 102H3 – SW 122H3 blue NTC9 brown / blue white green yellow pink NTC13 NTC14 white / blue grey / brown pink / brown violet grey / pink Black red / blue white / green Orange Yellow /2.D6 Subject to change without notice | 83056800fUK –...
SW 142H3 – SW 192H3 Circuit diagram 1/3 Subject to change without notice | 83056800fUK – Translation of the original operating manual | ait-deutschland GmbH...
Page 54
Circuit diagram 2/3 SW 142H3 – SW 192H3 OUT1 OUT6 white / yellow brown / green PWM1 PWM2 Subject to change without notice | 83056800fUK – Translation of the original operating manual | ait-deutschland GmbH...
Page 55
SW 142H3 – SW 192H3 Circuit diagram 3/3 blue NTC9 brown / blue white green yellow pink NTC13 NTC14 white / blue grey / brown pink / brown violet Black grey / pink red / blue Orange white / green Yellow /2.D6 Subject to change without notice | 83056800fUK –...
Page 56
Subject to change without notice | 83056800fUK – Translation of the original operating manual | ait-deutschland GmbH...
Page 57
Subject to change without notice | 83056800fUK – Translation of the original operating manual | ait-deutschland GmbH...
Page 58
Subject to change without notice | 83056800fUK – Translation of the original operating manual | ait-deutschland GmbH...
In the event of modification of the device(s) without our approval, this declaration shall become invalid. Designation of the device(s) Heat Pump Unit model Number Unit model Number SW 42H3 10070041 SW 42H1 10074042 SW 82H3 10070241 SW 62H1 10074142...
Page 60
GmbH Industriestraße 3 D-95359 Kasendorf E info@alpha-innotec.de W www.alpha-innotec.de alpha innotec – an ait-deutschland GmbH brand...
Need help?
Do you have a question about the SW 42H3 and is the answer not in the manual?
Questions and answers