■ DeviceNet Unit
Unit
Product
Specifications
type
name
DeviceNet
Functions as
Unit
master and/or
CS1
slave; allows
CPU
control of
Bus
32,000 points
Unit
max. per
master.
■ CompoNet Master Unit
Specifications
Unit
Product
Communications
type
name
functions
CompoNet
Master Unit
• Remote I/O
CS1
communications
Special
• Message
I/O Unit
communications
■ CompoBus/S Master Unit
Specifications
Unit
Product
Communications
type
name
functions
CompoBus/
S Master
Unit
CS1
Remote I/O
Special
communications
I/O Unit
■ ID Sensor Units
Number
Unit
Product
Connecting
type
name
ID System
V680-series
ID Sensor
RFID system
Units
CS1
Special
I/O Unit
V600-series
RFID system
* The current consumption is 0.28 A when connected to the V680-H01. For details, refer to the V680 Series RFID System Catalog (Cat. No. Q151).
44
Programmable Controllers SYSMAC
CPU Rack C200HX/
Communications
HG/HE
functions
Expansion
CS1W-BC
I/O Rack
@@3 @@2
• Remote I/O
Master
communications
Yes
Yes
(Fixed or user-set
allocation)
• Remote I/O Slave
communications
(Fixed or user-set
allocation)
Maximum number of Units: 16 if Configurator is used
• Message
communications
Maximum
CPU Rack C200HX/
number of I/O
HG/HE
points per
Expansion
CS1W-BC
Master
I/O Rack
@@3 @@2
Word Slave
Units:
1,024 inputs
and 1,024
outputs
(2,048 I/O
points total)
Yes
Yes
Bit Slave Units:
256 inputs
and 256
outputs (512
I/O points
total)
Maximum
CPU Rack C200HX/
number of I/O
HG/HE
points per
Expansion
CS1W-BC
Master
I/O Rack
@@3 @@2
256 max.
(128 inputs and
128 outputs)
Yes
Yes
128 max.
(64 inputs and
64 outputs)
External
CPU Rack C200HX/
of RW
power
HG/HE
Heads
supply
Expansion
CS1W-BC
I/O Rack
@@3 @@2
Not
1
Yes
Yes
required
2
24 VDC
Yes
Yes
Not
1
Yes
Yes
required
2
24 VDC
Yes
Yes
Mountable Racks
CS1
CS1 Long-
SYSMAC
Expansion
distance
BUS
Rack
Expansion
Slave
CS1W-BI
Rack
Rack
@@3 @@2
No
Yes
Yes
Yes
No
Mountable Racks
CS1
CS1 Long-
SYSMAC
Expansion
distance
BUS
Rack
Expansion
Slave
CS1W-BI
Rack
Rack
@@3 @@2
No
Yes
Yes
Yes
No
Mountable Racks
CS1
CS1 Long-
SYSMAC
Expansion
distance
BUS
Rack
Expansion
Slave
CS1W-BI
Rack
Rack
@@3 @@2
No
Yes
Yes
Yes
No
Mountable Racks
CS1
Expansion
CS1 Long-
SYSMAC
Rack
distance
BUS
Expansion
Slave
CS1W-BI
Rack
Rack
@@3 @@2
No
Yes
Yes
Yes
No
No
Yes
Yes
Yes
No
No
Yes
Yes
Yes
No
No
Yes
Yes
Yes
No
CS1G/H
Current
No. of
consumption
unit
(A)
Model
numbers
allocated
5 V
26 V
system
system
1 unit
number's
0.29
---
CS1W-DRM21-V1
words
Current
No. of
consumption
unit
(A)
Model
numbers
allocated
5 V
26 V
system
system
1, 2, 4, or
8 unit
numbers'
0.40
---
CS1W-CRM21
words
(variable)
Current
No. of
consumption
unit
(A)
Model
numbers
allocated
5 V
26 V
system
system
2 unit
numbers'
words
0.15
---
CS1W-SRM21
1 unit
number's
words
Current
No. of
consumption
unit
(A)
Model
numbers
allocated
5 V
26 V
system
system
*
1 unit
number's
0.26
0.13
CS1W-V680C11
words
2 unit
numbers'
0.32
---
CS1W-V680C12
words
1 unit
number's
0.26
0.12
CS1W-V600C11
words
2 unit
numbers'
0.32
---
CS1W-V600C12
words
Standards
UC1, N, L,
CE
Standards
U, U1, L,
N, CE
Standards
UC, CE
Standards
UC, CE