Introduction - Cortalk RMU5 Generic Installation And Configuration Manual

Table of Contents

Advertisement

1 Introduction

The RMU5 is a powerful remote monitoring unit with an optional precision GPS interruption controller for use with
cathodic protection rectifiers. Precise timing accuracy and repeatability is attained with GPS and microprocessor
technology. A small physical size and wide operating temperature range make this device ideally suited for use in a
variety of rectifier cabinets.
The basic RMU5 has the following feature set:
High-performance 200MHz ARM9-based processing platform
64MB RAM
32MB Flash storage for OS and applications
Windows Embedded CE 6.0 operating system
Integral health monitoring of internal voltages and temperature
20x4 character wide-temperature range LCD screen for local status monitoring with no additional equipment
10/100Base-T Ethernet for communications backhaul over various data networks
RS-232 MODBUS interface port for attachment to other SCADA RTUs
USB peripheral with RNDIS characteristics for configuration from a PC
USB host for additional USB flash drive or communications expansion
One digital input capable of dry contact or voltage input (optically isolated)
One ground switched digital output with 750mA sinking capability and 12V power
Four galvanically isolated bi-polar analog input channels configurable for +/-158mV, +/-7.5V, and +/-
150VDC ranges
24VAC/DC main power input, used with external Class 2 power transformer or external DC-DC converter
Battery backup allowing up to 8 hours of operation during main power fail conditions
Easy configuration through a PC-based graphical user interface
Remote configuration through available communications channels
Remote firmware updates over appropriate communications channels
Scheduler for future rectifier interruption cycles
Scheduler for input datalogging
Programmable alarm window capability on all input channels
NEMA 4X, IEC529 Type IP65 enclosure for harsh environments
CSA and UL approvals
°
Operation in -40
C to +60
The base product can be augmented through the following optional components:
Optional GPS time synchronized rectifier interruption
Internal Flash drive for datalogging storage (128MB to 8GB, factory installed)
Bluetooth communications for configuration and data retrieval
RS-232 communications expansion interface (same physical connector as MODBUS interface listed above)
o
Iridium SBD satellite modem
o
Skywave Inmarsat D satellite modem
o
V.34 PSTN modem
o
1200/2400 MSK VHF/UHF terrestrial radio modem
o
Third-party radio modems
Sensor expansion bus
o
Galvanically isolated 4 channel analog input module
o
Galvanically isolated 4 channel input + 4 channel output module
o
Isolated DC current sensor
o
High voltage 500V AC analog input module
o
External temperature sensor
o
High impedance analog inputs for reference half-cell measurements
o
Additional modules added in the future as required
This document details the installation and operation of the Mobiltex
MOBILTEX® DATA LTD.
Calgary, Alberta
°
C ambient temperatures
TITLE:
RMU5 Generic Installation and Configuration Guide
DOCUMENT NO.:
SHEET:
RMU5-MAN-001
®
RMU5 remote monitoring unit product.
REV:
6 of 69
1.10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents