4 Installation

4.1 Mounting

The RMU5 is housed in a weather-proof compact enclosure with a versatile mounting plate. Installation of the device
can be made inside a rectifier cabinet, or externally on a flat surface or pole. Figure 4 shows the dimensions of the
mounting plate, including the location and size of the mounting holes. Any of the available mounting holes may be used
to secure the RMU5 to a flat surface. The RMU5 may also be secured to a pole by utilizing pipe clamps through the
two slots on the top of the mounting plate and the two slots on the bottom of the mounting plate.

Figure 4 RMU5 Mounting Plate Dimensions

Once the RMU5 is attached to its final mounting location, cabling must be brought into the box through waterproof
conduit, or through sealing glands. Installation of the cabling feed-through must be made in such a manner that does
not degrade the environmental sealing characteristics of the RMU5.
MOBILTEX® DATA LTD.
Calgary, Alberta
TITLE:
RMU5 Generic Installation and Configuration Guide
DOCUMENT NO.:
SHEET:
RMU5-MAN-001
REV:
12 of 69