Ac Solid State Relays; Figure 11 Dc Solid State Mosfet Relay Installation; Figure 12 Mobiltex Standard Single Phase Solid State Ac Relays - Cortalk RMU5 Generic Installation And Configuration Manual

Table of Contents

Advertisement

L1
N/L2
Rectifier Transformer
Rectifier Assembly

Figure 11 DC Solid State MOSFET Relay Installation

4.2.5.1 AC Solid State Relays

The preferred relay to use in most cases is the AC solid state TRIAC relay on the primary-side of the rectifier transformer.
Mobiltex has several standard AC relays and heatsinks available as optional components for the RMU5.
K0513245010
AC Relay - 24-280 VAC RMS 50 Amps max. 0-8A=No Heatsink, 8-50A=HE-54
K0513211010
AC Relay - 24-280 VAC RMS 110 Amps max. 0-8A=No Heatsink, 8-60A=HE-54, 60-110A=HE-90
K0513285010
AC Relay - 48-530 VAC RMS 50 Amps max. 0-8A=No Heatsink, 8-50A=HE-54

Figure 12 Mobiltex Standard Single Phase Solid State AC Relays

All 3 relays are about the same physical size and look very similar. The heatsink requirements are listed above. These
relays can be used to either interrupt the primary line AC (for 120 & 230 volt rectifiers) or the secondary AC of the
rectifier.
K05232R5016
AC Relay - 3 phase, 48-530 VAC RMS 50 Amps max. 0-4A=No Heatsink, 4-30A=HE-90
MOBILTEX® DATA LTD.
Calgary, Alberta
DC Solid State MOSFET Relay Installation
-
+
~
-
-
+
Rectifier
Bridge
~
+
Transient Protection
Diode
TITLE:
RMU5 Generic Installation and Configuration Guide
DOCUMENT NO.:
RMU5-MAN-001
Relay is polarity sensitive on
both the control input and
contacts.
Flyback protection diode and
transient protection diode
must be selected according to
relay manufacturer's
specifications.
Normally Open DC
Solid State MOSFET
Relay
Flyback Protection
Diode
SHEET:
19 of 69
Protected
Structure
REV:
1.10

Hide quick links:

Advertisement

Table of Contents
loading