9. Megging

Megging of an installation incorporating a GRUND-
FOS MAGNA pump is not allowed, as the built-in
electronics may be damaged. If megging of the pump
is necessary, the pump should be electrically sepa-
rated from the installation.
Megging of the pump can be carried out as de-
scribed below.
Megging of pumps
1.
Switch off the electricity supply.
2.
Remove the wires from terminals L and N and the earth
conductor.
3.
Short-circuit terminals L and N using a short wire (see
B).
4.
Remove the screw for electronics frame connection
(see A).
5.
Test between terminals L/N and earth (see C).
Maximum test voltage: 1500 VAC/DC.
Note: Never test between supply terminals (L and N).
Maximum permissible leakage current: < 20 mA.
6.
Fit the screw for electronics frame connection (see A).
7.
Remove the short wire between terminals L and N
(see B).
8.
Fit the supply wires to terminals L and N and the earth
conductor.
9.
Switch on the electricity supply.