Siemens 7SR12 Argus Manual page 220

Overcurrent relay energy management
Hide thumbs Also See for 7SR12 Argus:
Table of Contents

Advertisement

7SR120 Technical Manual
OBJECT
Object
Variation
Number
16-Bit Binary Counter
20
6
32-Bit Delta Counter
20
7
16-Bit Delta Counter
20
8
21
0
32-Bit Frozen Counter
21
1
16-Bit Frozen Counter
21
2
32-Bit Frozen Delta
21
3
Counter (with Flag)
16-Bit Frozen Delta
21
4
Counter (with Flag)
32-Bit Frozen Counter
21
5
(without Time Of Freeze)
16-Bit Frozen Counter
21
6
(without Time Of Freeze)
32-Bit Frozen Delta Counter
21
7
(with Time Of Freeze)
16-Bit Frozen Delta Counter
21
8
(with Time Of Freeze)
9 (default -
32-Bit Frozen Counter
21
see note 1)
16-Bit Frozen Counter
21
10
32-Bit Frozen Delta Counter
21
11
16-Bit Frozen Delta Counter
21
12
Counter Change Event
22
0
1 (default -
32-Bit Counter Change
22
see note 1)
Event (without Time)
16-Bit Counter Change
22
2
Event (without Time)
32-Bit Delta Counter
22
3
16-Bit Delta Counter
22
4
32-Bit Counter Change
22
5
16-Bit Counter Change
22
6
Chapter 4 - Page 52 of 84
Function Codes
Description
(dec)
1 (read)
(without Flag)
(without Flag)
(without Flag)
Frozen Counter
1 (read)
- Any Variation
22 (assign class)
1 (read)
(with Flag)
1 (read)
(with Flag)
1 (read)
1 (read)
1 (read)
(without Flag)
1 (read)
(without Flag)
(without Flag)
(without Flag)
1 (read)
- Any Variation
1 (read)
1 (read)
Change Event
(without Time)
Change Event
(without Time)
1 (read)
Event (with Time)
1 (read)
Event (with Time)
REQUEST
(Library will parse)
Qualifier Codes
(hex)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
06 (no range, or all)
07, 08 (limited qty)
06 (no range, or all)
07, 08 (limited qty)
(unsol. resp)
06 (no range, or all)
07, 08 (limited qty)
(unsol. resp)
06 (no range, or all)
07, 08 (limited qty)
(unsol. resp)
06 (no range, or all)
07, 08 (limited qty)
© 2017 Siemens Protection Devices Limited
RESPONSE
(Library will respond with)
Function
Qualifier Codes
Codes
(hex)
(dec)
00, 01 (start-stop)
129
17, 28 (index
(response)
- see note 2)
00, 01 (start-stop)
129
17, 28 (index
(response)
- see note 2)
00, 01 (start-stop)
129
17, 28 (index
(response)
- see note 2)
00, 01 (start-stop)
129
17, 28 (index
(response)
- see note 2)
00, 01 (start-stop)
129
17, 28 (index
(response)
- see note 2)
00, 01 (start-stop)
129
17, 28 (index
(response)
- see note 2)
00, 01 (start-stop)
129
17, 28 (index
(response)
- see note 2)
129
(response)
17, 28 (index)
130
129
(response)
17, 28 (index)
130
129
(response)
17, 28 (index)
130
129
(response)
17, 28 (index)
130

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7sr11 argus

Table of Contents