Siemens 7SR12 Argus Manual page 103

Overcurrent relay energy management
Hide thumbs Also See for 7SR12 Argus:
Table of Contents

Advertisement

Instrument
ENERGY METERS
→to view
Active Energy
Exp
0.00MWh
Imp
0.00MWh
Reactive Energy
Exp
Imp
WATTMETRIC METERS
→to view
Ires R
Pres
Ires R Angle
I0-V0 Angle
DIRECTIONAL METERS
→to view
P/F Dir (67)
------------------------------------------------------
No Dir, PhA Fwd, PhA Rev, PhB Fwd,
PhB Rev, PhC Fwd, PhC Rev
Calc E/F Dir (67N)
------------------------------------------------------
No Dir, E/F Fwd, E/F Rev
Meas E/F Dir (67G)
------------------------------------------------------
No Dir, E/F Fwd, E/F Rev
SEF Dir (67SEF)
------------------------------------------------------
No Dir, SEF Fwd, SEF Rev
THERMAL METERS
→to view
Thermal Status
Phase A
Phase B
Phase C
FREQUENCY METERS
→to view
Frequency
Last Trip
AUTORECLOSE METERS
→to view
Autoreclose Status
79 AR State
AR Close Shot
MAINTENANCE METERS
→to view
CB Total Trips
Count
Target
©2017 Siemens Protection Devices Limited
This is the sub-group that includes all the meters that are
associated with Energy TEST/RESET ► allows access to this sub-
group
Displays both imported and exported Active Energy
Displays both imported and exported Reactive Energy
0.00MVArh
0.00MVArh
This is the sub-group that includes all the meters that are
associated with Wattmetric TEST/RESET ► allows access to this
sub-group
0.0xIn W
The Wattmetric component of residual current
0.0 xIn W
Wattmetric residual power
0.0º
Compensated residual phase angle
0.0º
Applied residual phase angle
This is the sub-group that includes all the meters that are
associated with Directional elements TEST/RESET ► allows
access to this sub-group. Only on models that have the 67 option
The appropriate values from the selection will be displayed.
The appropriate values from the selection will be displayed.
The appropriate values from the selection will be displayed.
The appropriate values from the selection will be displayed.
This is the sub-group that includes all the meters that are
associated with Thermal TEST/RESET ► allows access to this
sub-group
Displays the thermal capacity
0.0%
0.0%
0.0%
This is the sub-group that includes all the meters that are
associated with Thermal TEST/RESET ► allows access to this
sub-group
0.000Hz
Displays the frequency
0.000Hz
This is the sub-group that includes all the meters that are
associated with Autoreclose TEST/RESET ► allows access to this
sub-group. Only seen on models that have the 79 option
0
This is the sub-group that includes all the meters that are
associated with Maintenance TEST/RESET ► allows access to
this sub-group
Displays the number of CB trips experienced by the CB
0
100
7SR11 & 7SR12 Settings & Instruments Guide