Table 2.2. Installation Environment Requirements
Parameter
Allowable instantaneous
Power supply
power outage
specifications
Dielectric strength
Operating temperature
Storage temperature
Humidity *1
Floating dust particles
Corrosive gases
Ambient
specifications
Line-noise
resistance
Vibration
resistance *2
Impact resistance *2
Grounding
*1 When a floppy disk is not in use.
*2 When the HDD and FDD are not in use.
User's Manual
Less than 20ms
One minute each for 3.0 kVAC (input-output), 2.0 kVAC (input-FG),
and 0.5 kVAC (output-FG)
50MΩ (DC500V)
0 - 50°C(SDD in use)
5 - 45°C(HDD in use)
5 - 45°C(FDD in use)
-10 - 60°C
10 - 90%RH(No condensation)
Not to be excessive
None
AC line/±2kV, Signal line/
Line noise
±1kV (IEC1000-4-4Level 3, EN61000-4-4Level 3)
Static
Contact discharge/±4kV (IEC1000-4-2Level 2, EN61000-4-2Level 2)
electricity
Atmospheric discharge/±8kV (IEC1000-4-2Level 3, EN61000-4-2Level 3)
resistance
10 - 57Hz/semi-amplitude 0.15mm 57 - 150Hz/2.0G
Sweep
80 min. each in x, y, and z directions
resistance
(JIS C0040-compliant, IEC68-2-6-compliant)
10G, half-sine shock for 11 ms in x, y, and z directions
(JIS C0041-compliant, IEC68-2-27-compliant)
Class D grounding (previous class 3 grounding)