Service Manual - SVH 09/12/18/24 Series
○
3
3) Pull out connectors of
the condenser coil temp.
sensor (T3),outdoor
ambient temp. sensor
(T4) and discharge temp.
sensor (T5).
4) Disconnect the
○
4
electronic expansion
valve wire.
5) Remove the
grounding screw.
○
○
5
6
6) Remove the
Wires (1,2,3). Then
remove the electronic
control box.
76