COMFORT-AIRE B-SVH24SA-1 Service Manual page 55

Century svh series inverter single zone ductless mini-split
Table of Contents

Advertisement

Service Manual - SVH 09/12/18/24 Series
3. IPM continuity check
Turn off the power, let the large capacity electrolytic capacitors discharge completely, and dismount the IPM. Use a digital
tester to measure the resistance between P and UVWN; UVW and N.
Digital tester
(+)Red
(-)Black
N
U
P
V
W
4. Fan Motor
Measure the resistance value of each winding by using the tester.
Model
Brand
Black – Red
Main
Blue –Black
AUX
Normal resistance value
(Several MΩ)
YKT-32-6-202L
YKT-32-6-3L
Tongde
Ω
86
Ω
64
Digital tester
(+)Red
(-)Black
U
V
N
W
(+)Red
YKT-48-6-206
Welling
Welling
213
152
156
142
55
Normal resistance value
(Several MΩ)
YKT-63-6-200L
Welling
88.5
138