COMFORT-AIRE B-SVH24SA-1 Service Manual page 25

Century svh series inverter single zone ductless mini-split
Table of Contents

Advertisement

Service Manual - SVH 09/12/18/24 Series
details are as follows.
Enquiry
Display value
information
T1,T2,T3,T4,
-1F,-1E,-1d,-1c,-
T2B,TP,TH,
1b,-1A
Targeted
-19—99
Frequency,
A0,A1,...A9
Actual
b0,b1,...b9
Frequency
c0,c1,...c9
d0,d1,...d9
E0,E1,...E9
F0,F1,...F9
Indoor fan
0
speed
1,2,3,4
/Outdoor fan
speed
14-FF
EXV opening
0-FF
angle
Compressor
0-FF
continuous
running time
Causes of
0-99
compressor
stop.
Reserve
0-FF
Reserve
2~28
Reserve
5~20
Reserve
5~25
Meaning
Remark
-25,-24,-23,-22,-21,-2
1. All the displaying temperature is actual
0
2. All the temperature is °C no matter what
-19—99
kind of remote controller is used.
100,101,...109
3. T1,T2,T3,T4,T2B display range:-25~70,
110,111,...119
TP display range:-20~130.
120,121,...129
4. Frequency display range: 0~159HZ.
130,131,...139
5. If the actual value exceeds the range, it
140,141,...149
will display the maximum value or minimum
150,151,...159
value.
OFF
Low speed, Medium
For some big capacity motors.
speed, High speed,
Turbo
Actual fan
For some small capacity motors,
speed = Display
display value is from 14-FF(hexadecimal),
value x 10. The unit
the corresponding fan speed range is from
is RPM.
200-2550RPM.
Actual EXV opening
value=Display value
turns to decimal
value and then
multiply 2.
0-255 minutes
If the actual value exceeds the
range, it will display the maximum
value or minimum value.
For the detailed
Decimal display
meaning, please
consult with engineer
25
value.