COMFORT-AIRE B-SVH24SA-1 Service Manual page 35

Century svh series inverter single zone ductless mini-split
Table of Contents

Advertisement

Service Manual - SVH 09/12/18/24 Series
Remark:
Use a multimeter to test the DC voltage
between 2 port and 3 port of outdoor unit.
The red pin of multimeter connects with 2
port while the black pin is for 3 port.
When AC is running normally, the
voltage will move alternately between
-25V to 25V.
If the outdoor unit has malfunction, the
voltage will move alternately with
positive value.
While if the indoor unit has malfunction,
the voltage will be a certain value.
Remark:
Use a multimeter to test the resistance
of the reactor which does not connect
with capacitor.
The normal value should be around
zero ohms. Otherwise, the reactor is
malfunctioning.
35
31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents