2. Compressor checking
Measure the resistance value of each winding by using the tester.
Position
Blue - Red
Blue - Black
Red - Blue
Resistance Value
ASN98D22UFZ
ASM135D23UFZ
1.57Ω
Service Manual - SVH 09/12/18/24 Series
ATF235D22UMT
1.75 Ω
0.75 Ω