Pushbutton Fault Light Indicator

An optional pushbutton/fault light can be mounted in the cab that monitors the status of the lube
system. The LED uses different flashing frequencies depending on the status of the lube system (i.e.
running, not running or in fault). The service manual for the particular pump will show what fault is
associated with each flashing frequency.
1. Manual Lube: By depressing the pushbutton for 2 seconds, the operator can initiate a
manual lube event. The pump will stay on a pre-determined amount of time or until the
proximity switch turns it off.
2. Indication of operation: The lamp will be on constantly.
3. Fault Indication: A flashing LED indicates a fault. Refer to the pump technical manual
for the flashing frequency definitions of the various faults (i.e. low level, blockage or
drive motor malfunction)
The Red pushbutton is used exclusively with the
Data-Logger pumps. The status of the lube
systems is indicated by whether the light is on or
off.
LED Off – Indication of Operation
LED On – Fault in system (action required)