Quick-Fill Adapter Installation and Operation (Filling pump reservoir)
The Quick-Fill adapter is a device which replaces
the standard grease fitting fill port with a high-flow
port for use with a standard grease gun.
Step 2: Insert the Quick-Fill adapter into the fill
port. Hand tighten only.
Step 4: Insert a new cartridge of grease into the
grease gun's container tube and assemble into
the quick-fill adapter.
Step 1: To install the quick-fill adapter, remove the
standard fill port located in the front of the pump.
Step 3: To fill the reservoir, remove the grease
gun's pump head assembly from the container
tube (Standard procedure used to install a
lubricant cartridge).
Step 5: Unlock the follower handle making sure
the handle is engaged with the follower. Push the
follower rod handle into the container. This action
will dispense the entire cartridge of grease into the
reservoir. Repeat until the reservoir is full. Replace
quick-fill cap.