Daily Walk-Around Inspection

The Lincoln Industrial Quicklub automated lube system components are designed, engineered,
manufactured and assembled to the highest or quality standards. This lube system requires little or nor
maintenance, however, to ensure maximum reliability and to realize maximum service life of all
components, it is recommended that a daily walk-around inspection be performed.
The daily walk-around inspection should include the following:
Observe lubricant level in reservoir. Fill reservoir if it is low.
Inspect high pressure relief at pump element, noting any lubricant buildup. If buildup is observed,
correct this problem by determining cause of blockage.
Inspect all valve and lube point connections to verify that no leaks are occurring.
Inspect supply/feed lines to insure that no breaks or leaks have occurred.
Inspect lube points to ensure that all lube points have a "fresh grease appearance."
Check pump operation by depressing push-button located in base of pump for two seconds to
initiate a manual lube event. This will verify that pump is working (ignition switch must be on).
Report or repair any problems found in this walk-around inspection immediately.
NOTE: Operator to confirm operation of electric pump while machine is in service.
NOTE: Report or repair any problem detected from daily inspection.