GE Multilin UR Series N60 Instruction Manual page 467

Network stability and synchrophasor measurement system
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 56 of 57)
ADDR
REGISTER NAME
D3D8
...Repeated for Remote Device 23
D3DC
...Repeated for Remote Device 24
D3E0
...Repeated for Remote Device 25
D3E4
...Repeated for Remote Device 26
D3E8
...Repeated for Remote Device 27
D3EC
...Repeated for Remote Device 28
D3F0
...Repeated for Remote Device 29
D3F4
...Repeated for Remote Device 30
D3F8
...Repeated for Remote Device 31
D3FC
...Repeated for Remote Device 32
Phasor Measurement Unit Communication (Read/Write Setting)
D715
PMU 1 Port 2 D-CH-x Normal State (16 items)
D725
PMU 1 Port 3 D-CH-x Normal State (16 items)
D835
...Repeated for PMU 2
DC6A
...Repeated for PMU 3
E09F
...Repeated for PMU 4
Phasor Measurement Unit Recording Command (Read/Write Command)
E4D4
PMU 1 Recording Clear Command
E4D5
PMU 1 Recording Force Trigger
E4D6
...Repeated for PMU 2
E4D8
...Repeated for PMU 3
E4DA
...Repeated for PMU 4
Phasor Measurement Unit Recording (Read/Write Setting)
E4DD
Reserved
E4DE
PMU 1 No Of Timed Records
E4DF
PMU 1 Trigger Mode
E4E0
PMU 1 Timed Trigger Position
E4E1
Reserved
E4E2
PMU 1 Record PHS-1 (14 items)
E4F0
PMU 1 Record PHS-x Name (14 items)
E560
PMU 1 Record A-CH-x (8 items)
E568
PMU 1 Record A-CH-x Name (8 items)
E5A8
PMU 1 Record D-CH-x (16 items)
E5B8
PMU 1 Record D-CH-x Name (16 items)
E636
PMU 1 Record Function
E638
...Repeated for PMU 2
E794
...Repeated for PMU 3
E8F0
...Repeated for PMU 4
Phasor Measurement Unit Frequency Trigger (Read/Write Setting)
EB00
PMU 1 Frequency Trigger Function
EB01
PMU 1 Frequency Trigger Low Frequency
EB02
PMU 1 Frequency Trigger High Frequency
EB03
PMU 1 Frequency Trigger Pickup Time
EB04
PMU 1 Frequency Trigger Dropout Time
EB05
PMU 1 Frequency Trigger Block (3 items)
EB08
PMU 1 Frequency Trigger Target
EB09
PMU 1 Frequency Trigger Events
EB0A
...Repeated for PMU 2
EB14
...Repeated for PMU 3
EB1E
...Repeated for PMU 4
Direct integers (read/write setting registers)
EC40
Direct integer output 1 value
EC41
Direct integer output 1 trigger
EC42
Direct integer input 1 device
GE Multilin
N60 Network Stability and Synchrophasor Measurement System
RANGE
UNITS
STEP
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
---
---
1
1 to 128
---
1
0 to 1
---
1
1 to 50
%
1
---
---
1
0 to 14
---
1
---
---
---
0 to 65535
---
1
---
---
---
0 to 65535
---
1
---
---
---
0 to 1
---
1
0 to 1
---
1
20 to 70
Hz
0.01
20 to 70
Hz
0.01
0 to 600
s
0.01
0 to 600
s
0.01
0 to 65535
---
1
0 to 2
---
1
0 to 1
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 16
---
1
B.4 MEMORY MAPPING
FORMAT
DEFAULT
F108
0 (Off)
F108
0 (Off)
F126
0 (No)
F126
0 (No)
F001
0
F001
3
F542
0 (Auto Overwrite)
F001
10
F001
0
F543
1 (Va)
F203
GE-UR-PMU-PHS 1
F600
0
F203
AnalogChannel 1
F300
0
F203
Dig Channel 1
F102
0 (Disabled)
F102
0 (Disabled)
F001
4900
F001
6100
F001
10
F001
100
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F612
0
F300
0
F001
0
B-63
B

Advertisement

Table of Contents
loading

Table of Contents