GE Multilin UR Series N60 Instruction Manual page 446

Network stability and synchrophasor measurement system
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 35 of 57)
ADDR
REGISTER NAME
9BB0
Teleprotection Input 1 States, 1 per register (16 items)
9BC0
Teleprotection Input 2 States, 1 per register (16 items)
VT Fuse Failure (Read/Write Setting) (6 modules)
A09A
VT Fuse Failure Function
A09B
VT Fuse Failure Neutral Wire Open Function
B
A09C
VT Fuse Failure Neutral Wire Open 3rd Harmonic Pickup
A041
...Repeated for module number 2
A042
...Repeated for module number 3
A043
...Repeated for module number 4
A044
...Repeated for module number 5
A045
...Repeated for module number 6
Summator settings (read/write, 6 modules)
A0AC
VTFF x V0 3rd harmonic
A0C0
Summator 1 function
A0C1
Summator 1 input mode
A0C2
Summator 1 hold
A0C3
Summator 1 pickup
A0C5
Summator 1 hysteresis
A0C6
Summator 1 input
A0CC
Summator 1 scale factor
A0D8
Summator 1 position selector
A0DE
Summator 1 units
A0E0
Summator 1 events
A0E1
Summator 1 per-unit base
A0E3
...Repeated for summator 2
A106
...Repeated for summator 3
A129
...Repeated for summator 4
A14C
...Repeated for summator 5
A16F
...Repeated for summator 6
Selector switch actual values (read only)
A210
Selector switch 1 position
A211
Selector switch 2 position
Selector switch settings (read/write, 2 modules)
A280
Selector 1 Function
A281
Selector 1 Range
A282
Selector 1 Timeout
A283
Selector 1 Step Up
A284
Selector 1 Step Mode
A285
Selector 1 Acknowledge
A286
Selector 1 Bit0
A287
Selector 1 Bit1
A288
Selector 1 Bit2
A289
Selector 1 Bit Mode
A28A
Selector 1 Bit Acknowledge
A28B
Selector 1 Power Up Mode
A28C
Selector 1 Target
A28D
Selector 1 Events
A28E
Reserved (10 items)
A298
...Repeated for Selector 2
DNP/IEC Points (Read/Write Setting)
A300
DNP/IEC 60870-5-104 Binary Input Points (256 items)
A400
DNP/IEC 60870-5-104 Analog Input Points (256 items)
Non Volatile Latches (Read/Write Setting) (16 modules)
A700
Non-Volatile Latch 1 Function
B-42
–2000000 to 2000000
N60 Network Stability and Synchrophasor Measurement System
RANGE
UNITS
STEP
0 to 1
---
0 to 1
---
0 to 1
---
0 to 1
---
0 to 3
pu
0.001
0 to 999999.999
V
0.001
0 to 1
---
0 to 1
---
0 to 65535
---
---
0.001
0.1 to 50
%
0 to 65535
---
–2000 to 2000
---
0.000001
0 to 65535
---
---
---
0 to 1
---
1 to 2000000
---
1 to 7
---
1 to 7
---
0 to 1
---
1 to 7
---
3 to 60
s
0 to 65535
---
0 to 1
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 1
---
0 to 65535
---
0 to 2
---
0 to 2
---
0 to 1
---
---
---
0 to 65535
---
0 to 65535
---
0 to 1
---
APPENDIX B
FORMAT
DEFAULT
1
F108
0 (Off)
1
F108
0 (Off)
1
F102
0 (Disabled)
1
F102
0 (Disabled)
F001
100
F060
0
1
F102
0 (Disabled)
1
F515
0 (Signed)
1
F300
0
F004
1000000
0.1
F001
30
1
F600
0
F004
1000000
1
F300
0
---
F207
(none)
1
F102
0 (Disabled)
1
F004
1
1
F001
0
1
F001
1
1
F102
0 (Disabled)
1
F001
7
0.1
F001
50
1
F300
0
1
F083
0 (Time-out)
1
F300
0
1
F300
0
1
F300
0
1
F300
0
1
F083
0 (Time-out)
1
F300
0
1
F084
0 (Restore)
1
F109
0 (Self-reset)
1
F102
0 (Disabled)
1
F001
0
1
F300
0
1
F300
0
1
F102
0 (Disabled)
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents