B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 51 of 57)
ADDR
REGISTER NAME
CAE3
Direct I/O Ch 1 Unreturned Messages Alarm Events
CAE4
Reserved (4 items)
CAE8
Direct IO Ch 2 Unreturned Messages Alarm Function
CAE9
Direct I/O Ch 2 Unreturned Messages Alarm Msg Count
CAEA
Direct I/O Ch 2 Unreturned Messages Alarm Threshold
B
CAEB
Direct I/O Channel 2 Unreturned Messages Alarm Events
CAEC
Reserved (4 items)
Remote Devices (Read/Write Setting) (16 modules)
CB00
Remote Device 1 GSSE/GOOSE Application ID
CB21
Remote Device 1 GOOSE Ethernet APPID
CB22
Remote Device 1 GOOSE Dataset
CB23
Remote Device 1 in PMU Scheme
CB24
...Repeated for Device 2
CB48
...Repeated for Device 3
CB6C
...Repeated for Device 4
CB90
...Repeated for Device 5
CBB4
...Repeated for Device 6
CBD8
...Repeated for Device 7
CBFC
...Repeated for Device 8
CC20
...Repeated for Device 9
CC44
...Repeated for Device 10
CC68
...Repeated for Device 11
CC8C
...Repeated for Device 12
CCB0
...Repeated for Device 13
CCD4
...Repeated for Device 14
CCF8
...Repeated for Device 15
CD1C
...Repeated for Device 16
CD40
...Repeated for Device 17
CD64
...Repeated for Device 18
CD88
...Repeated for Device 19
CDAC
...Repeated for Device 20
CDD0
...Repeated for Device 21
CDF4
...Repeated for Device 22
CE18
...Repeated for Device 23
CE3C
...Repeated for Device 24
CE60
...Repeated for Device 25
CE84
...Repeated for Device 26
CEA8
...Repeated for Device 27
CECC
...Repeated for Device 28
CEF0
...Repeated for Device 29
CF14
...Repeated for Device 30
CF38
...Repeated for Device 31
CF5C
...Repeated for Device 32
Remote Inputs (Read/Write Setting) (64 modules)
CFA0
Remote Input 1 Device
CFA1
Remote Input 1 Item
CFA2
Remote Input 1 Default State
CFA3
Remote Input 1 Events
CFA4
Remote Input 1 Name
CFAA
...Repeated for Remote Input 2
CFB4
...Repeated for Remote Input 3
CFBE
...Repeated for Remote Input 4
CFC8
...Repeated for Remote Input 5
CFD2
...Repeated for Remote Input 6
B-58
N60 Network Stability and Synchrophasor Measurement System
RANGE
UNITS
STEP
0 to 1
---
1 to 1000
---
0 to 1
---
100 to 10000
---
1 to 1000
---
0 to 1
---
---
---
---
---
---
0 to 16383
---
0 to 16
---
0 to 1
---
1 to 16
---
0 to 64
---
0 to 3
---
0 to 1
---
1 to 64
---
APPENDIX B
FORMAT
DEFAULT
1
F102
0 (Disabled)
1
F001
10
1
F102
0 (Disabled)
1
F001
600
1
F001
10
1
F102
0 (Disabled)
1
F001
10
F209
"Remote Device 1"
1
F001
0
1
F184
0 (Fixed)
1
F126
0 (No)
1
F001
1
1
F156
0 (None)
1
F086
0 (Off)
1
F102
0 (Disabled)
1
F205
"Rem Ip 1"
GE Multilin