Setting Up a Mitel SX-200 Digital PIMG Integration with Cisco Unity Connection
Field
Password
1 Select OK.
2 On the System menu, select Upgrade.
3 On the Upgrade page, select Browse.
4 In the Choose File dialog box, browse to the directory on the Windows workstation that has the extracted
PIMG firmware update files.
5 Select Mtl_<xx > .app (where <xx> is multiple digits), and select Open.
6 On the Upgrade page, select Install File.
7 After the file is installed, a message prompting you to restart the PIMG unit appears. Select Cancel.
Do not restart the PIMG unit until you are instructed to do so later in this procedure, even if the file
installation fails. Restarting the PIMG unit at this step may prevent the PIMG unit from functioning
correctly.
8 Repeat
• Mtl_<xx>.fsh
• Run<xx>FskEcho.dsp
• Mtl<xx>.lca
9 On the Configuration menu, select Import/Export.
10 On the Import/Export page, select Browse.
11 In the Choose File dialog box, browse to the file MTLDNI_Cfg_Mitel.ini.
12 Select MTLDNI_Cfg_Mitel.ini, and select Open.
13 On the Import/Export page, select Import File.
14 After the file is imported, a message prompting you to restart the PIMG unit appears. Select OK.
15 In the web browser, go to http://10.12.13.74.
16 To sign in, enter the following case-sensitive settings.
Table 7: Sign-in Settings
Field
Username
Password
1 Select OK.
Setting
Enter IpodAdmin.
Step 6
through
Step 11
for each of the following files:
Setting
Enter admin.
Enter IpodAdmin.
Setting Up the Digital Mitel PIMG Units
PIMG Integration Guide for Cisco Unity Connection Release 11.X