Description Of Socket X3B; Input Signals Channel 2; 3.4.2.1 Serial Data Transmission; Figure 3: Socket X3B - KEB COMBIVERT F5 Instruction Manual

Encoder interface
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

Description of the Interface
3.4.1

Description of socket X3B

PIN
Name
1
CL+
2
DAT+
3
4
5 V
5
24 V
6
CL-
7
DAT-
8
9
COM
GND
Figure 3:
3.4.2

Input signals channel 2

3.4.2.1 Serial data transmission

Singleturn absolute encoder divide one revolution of the shaft into a defined number of meas-
uring steps. This are 4096 positions at a SSI protocol, corresponding to a resolution of 12 Bit.
Multiturn absolute encoder do not only detect angle positions within one revolution but also
the number of revolutions. With a resolution of the multiturn part of 12 Bit this corresponds to
4096 revolutions. The position measuring area of 0...2
flow and/or underflow is not evaluated as error. A system offset can be defined by writing on
Ec.34 or approaching to reference point.
10
Description
Output of the clock signal
Input data track
Voltage output 5 V
Voltage output 20...30 V
Difference signal to clock signal C+
Difference signal to data track DAT+
Reference potential for voltage supply
Connection for shield at connector housing - is directly connected with
the inverter earth.
Socket X3B
5
4
3
2
1
9
8
7
6
-1 should not be left, since an over-
24