4. After all contacts are inserted, close wedge lock to its
locked position. Release locking latches by squeezing
them inward.
Figure 7-17. Close Wedge Lock
5. Slide wedge lock in housing until flush with housing.
Figure 7-18. Seating Wedge Lock

Disassembly

1. Insert a 4.8 mm (3/16") wide screwdriver blade between
mating seal and one of red wedge lock tabs.
2. Pry wedge lock open.
3. While rotating wire back and forth over a half turn (1/4
turn in each direction), gently pull wire until contact is
removed.
3121290
SECTION 7 - BASIC ELECTRICAL INFORMATION & SCHEMATICS
NOTE: Wedge lock should never be removed from housing for
insertion or removal of contacts.
Figure 7-19. AMP Connector Disassembly

Wedge Lock

The wedge lock has slotted openings in the forward, or mating
end. These slots accommodate circuit testing in the field by
using a flat probe such as a pocket knife. DO NOT use a sharp
point such as an ice pick.

Service - Voltage Reading

HOLES IN WIRE INSULATION CAN LET IN MOISTURE AND CAUSE SYSTEM FAIL-
URE. DO NOT PIERCE WIRE INSULATION TO TAKE VOLTAGE READINGS.
It has been common practice in electrical troubleshooting to
probe wires by piercing insulation with a sharp point. This
practice should be discouraged when dealing with an
AMPSEAL plug assembly or any other sealed connector sys-
tem. Resulting pinholes in the insulation allows moisture to
enter by traveling along wire strands and could result in sys-
tem failure.