Preset Resolution
Custom Resolution

Step2: Screen Settings

The preconditions of quick screen settings is that the screen and cabinets must be
regular (not special-shaped) and the load of each cabinet is same.
Operating steps of screen settings:
Step 1
Switch on the screen. If cabinets display normally, move on to Step 2. If the
cabinets display abnormally, load cabinet file first and save it to receiving
card. See detailed operation in Advanced Settings ;
Step 2
Return to "Screen Settings" sub-menu. Rotate the button to switch to
sub-menus of other options respectively for configuration, as shown in the
following figures:
Brightness
Screen Settings
Input Settings
Output Settings
Step 3
Set Cabinet Row Qty and Cabinet Column Qty according to the actual
situation of the screen;
Step 4
Set Port1 Cabinet Qty. The device has some limitations on the cabinet
quantity of ports. For details, see precautions for screen settings;
Set Data Flow (Front View). Pay attention to precautions for screen settings c), d) and
e) below.
Precautions for screen settings:
(a) If the number of ports
with loads is n (n≤4), the first
n-1 ports must load the same
number of cabinets, which must
also be an integral multiple of
the number of cabinet rows or
columns and be greater than or
equal to the number of cabinets
for the nth ports.
(b) In the case of special-shaped cabinets, different cabinet sizes and special-
shaped screen, NovaLCT-Mars is required to be used to configure the screen.
V X S e r i e s U se r 's M a nu a l
Width (H)
Height(V)
Custom Refresh Rate
Apply
25%
Example:
For example, if port 1, port 2, port 3 have loads,
port 1 and port 2 must have the same number of
cabinets, which must also be an integral multiple
of the number of cabinet rows or columns.
Therefore, you only need to set port 1 cabinet Qty
according to the actual situation when setting the
screen. The number of receiving cards port 3 loads
must be smaller than or equal to port 1.
-9-
60Hz
1920
1080
59.94Hz
50Hz
30Hz
Cabinet Row Qty
Cabinet Column Qty
Port 1 Cabinet Qty
Data Flow(Front View)
3
3
4