3-3-7. WB Adjustment (3200K Preset and
WB Data Reading)
1. Press the step forward button of the commander one
time. Then, "1E" appears on the mode display.
2. Set the lens aperture of the VIDEO OUT image level
to the following specification.
Subject:
Measuring point:
Measuring equipment: Waveform monitor
Mode display:
Specification:
3. While changing the mode display between "1E" and
"1F" alternately using the mode display change button,
adjust so that the white luminescent spot matches with
the Vectorscope starting point using the data change
button.
Subject:
Measuring point:
Measuring equipment: Vectorscope
Mode display:
Specification:
Moving direction of white
luminescent spot when "1E" is
displayed on the mode display.
3-6
100% white pattern
Image level of VIDEO OUT
1E
65 ± 3 IRE
(SSC-DC593)
455 ± 20 mV
(SSC-DC593P/DC598P)
100% white pattern
White luminescent spot of
VIDEO OUT
1E, 1F
White luminescent spot
matches with the Vectorscope
starting point.
Moving direction of white
luminescent spot when "1F" is
displayed on the mode display.
3-3-8. Color Reproduction Adjustment
1. Press the step forward button of the commander one
time. Then, "0C" appears on the mode display.
2. Shoot the image of color bar chart.
3. Set the lens aperture of the VIDEO OUT white level to
the following specification.
Subject:
Measuring point:
Measuring equipment: Waveform monitor
Mode display:
Specification:
Color bar chart
Image level of VIDEO OUT
0C
90 ± 2.5 IRE
(SSC-DC593)
630 ± 15 mV
(SSC-DC593P/598P)
White image level