INSTALLING EXTENSIONS
Digital Extension Cabling
Each digital extension requires one-pair twisted cable from the MDF to the RJ11/RJ45 socket. Refer to
Section 7: Specifications and Parts List (page 7-1) for maximum cable lengths.
Installing a Key Telephone
1.
2.
3.
The ESIU extension ports are not polarity sensitive.
The system will automatically set the terminal type when the extension is plugged in for the first time.
Confirm the terminal type with Program 10-03. If you need to change the terminal type set Program
10-03 to un-used and then plug in the new extension, it will then be assigned automatically.
Aspila EX Hardware Manual
Chuyên phân phối tổng đài NEC
Section 3: Installing Extensions and Trunks
Install an RJ11/RJ45 socket for each extension. The socket should be within two metres of the
phone due to the length of the line cord supplied.
For each extension, run one-pair station cable to an RJ11 (or RJ45) socket.
Terminate the pair to pins 3 & 4 for the RJ11 socket (pins 4 & 5 of the RJ45 socket). Refer to
Digital Station (8/16ESIU) PCB (Figure 2-8) (page 2-17) for details of the RJ61 connector
pin outs.