Action in MELSAP-L (instruction format)
In MELSAP-L (instruction format), instructions for actions are described in text format in a SFC diagram.
To switch from detailed expression in ladder diagrams to MELSAP-L (instruction format), select [View] 
[Switch Ladder Display]  [MELSAP-L (Instruction Format)] from the menu. ( GX Works3 Operating
Manual)
For actions in MELSAP-L (instruction format), instructions and coils to output are described without contacts to be input
conditions of each instruction.
In MELSAP-L (instruction format), programs are described in the following format.
: Applicable label/device, Kn: Setting value of timer/counter
Item
Coil output (OUT instruction)
Setting devices (SET instruction)
Resetting devices (RST instruction)
Low-speed timer (OUT T instruction)
High-speed timer (OUTH T instruction)
*1
Counter (OUT C instruction)
*2
Instructions other than listed above
*1 Specify a long timer or a long counter in the same way.
*2 Some instructions cannot be used. (Page 106 Instructions that cannot be used)
To describe multiple instructions, delimit them by a comma (,). When using the IMASK or NOPLF instruction, describe them in the end of
the action.
MELSAP-L (instruction format)
o
s
r
*1
o Kn
h Kn
o Kn
Describe instructions in the same way as in ladder
diagrams.
Example
oY0
sM0
rM0
oT0 K100
hT1 K10
oC0 K10