Synchronizing Local Time Using Ntp - Brocade Communications Systems 5300 Hardware Installation Manual

Hide thumbs Also See for 5300:
Table of Contents

Advertisement

2.
Enter the tsTimeZone command as follows:
switch:admin> tstimezone [--interactive ]/ [, timezone_fmt]
Use timezone_fmt to set the time zone by Country/City or by time zone ID, such as PST.
The following example shows how to change the time zone to US/Central.
switch:admin> tstimezone
Time Zone : US/Pacific
switch:admin> tstimezone US/Central
switch:admin> tstimezone
Time Zone : US/Central
The following procedure describes how to set the current time zone using interactive mode to Pacific Standard Time.
1.
Type the tsTimeZone command as follows:
switch:admin> tstimezone --interactive
2.
You are prompted to select a general location.
Please identify a location so that time zone rules can be set correctly.
3.
Enter the appropriate number or Ctrl-D to quit.
4.
At the prompt, select a country location.
5.
At the prompt, enter the appropriate number to specify the time zone region or Ctrl-D to quit.

Synchronizing local time using NTP

Perform the following steps to synchronize the local time using NTP.
1.
Log into the switch using the default password, which is password.
2.
Enter the tsClockServer command:
switch:admin> tsclockserver "<ntp1;ntp2>"
where ntp1 is the IP address or DNS name of the first NTP server, which the switch must be able to access. The second ntp2 is
the second NTP server and is optional. The operand "<ntp1;ntp2>" is optional; by default, this value is LOCL, which uses the
local clock of the principal or primary switch as the clock server.
switch:admin> tsclockserver
LOCL
switch:admin> tsclockserver "132.163.135.131"
switch:admin> tsclockserver
132.163.135.131
switch:admin>
The following example shows how to set up more than one NTP server using a DNS name:
switch:admin> tsclockserver
"10.32.170.1;10.32.170.2;ntp.localdomain.net"
Updating Clock Server configuration...done.
Updated with the NTP servers
Changes to the clock server value on the principal or primary FCS switch are propagated to all
switches in the fabric.