Synchronizing the Local Time with an External Source

Perform the following steps to synchronize the local time of the principal or primary FCS device with that of an external NTP server.
1.
Log on as admin.
2.
Enter the tsClockServer [ipaddr] command.
The ipaddr variable represents the IP address of the NTP server that the device can access. This variable is optional; by
default, the value is LOCL.
switch:admin> tsclockserver 192.168.126.60
Updating Clock Server configuration...done.
Updated with the NTP servers

Customizing the Chassis Name and Switch Name

Changing the chassis and switch names is important for uniquely distinguishing and identifying the device and for accurate tracking of
logs and errors. The messages that appear in the log are labeled with the switch name or chassis name, which makes tracking the errors
much easier. Specify an easily understandable and meaningful name for the chassis and switch.
Perform the following steps to change the chassis name and then the switch name.
1.
Log on to the device through Telnet using the admin account.
2.
Change the chassis name by using the chassisName command.
device:admin> chassisname Chassis_001
3.
Change the switch name by using the switchName command.
device:admin> switchname Switch_001
Committing configuration...
Done
Switch name has been changed. Please re-login to the switch for the change to applied

Establishing an Ethernet Connection

Perform the following steps to establish an Ethernet connection to the device.
1.
Remove the plug from the Ethernet port.
2.
Connect an Ethernet cable to the device Ethernet port and to the workstation or to an Ethernet network that connects the
workstation.
NOTE
At this point, the device can be accessed remotely, using either the command line or Brocade Web Tools. Ensure that
the device is not being modified from any other connections during the remaining tasks in this chapter. The Ethernet
management port also supports Auto MDI/MDIX.