Components
External Luminaire Components
The following illustration shows the external luminaire components and controls.
Head Assembly
Houses color, gobos, strobe, iris
and zoom lens mechanisms
Input Panel
Provides DMX In and Thru,
and AC Power connections.
(see detail below)
Input Panel Components
Product Label ID
AC Input
02.96 98.001 0 0
Menu Display
Used to input manual
commands, program, test,
set defaults and access
internal status information.
~
DATA THRU
AC IN
DATA IN
MENU
Data In
Data Thru
C
: E
OMPONENTS
XTERNAL
ENTER
L
C
UMINAIRE
OMPONENTS
Backcap Assembly
Provides access to lamp
for replacement and
provides controls for
beam adjustment.
Yoke Assembly
Houses Master Control
Board (MCB), tilt motor,
ignitor, and cooling fans.
Upper Enclosure Assembly
Houses power supply, ballast,
and display board.
Beam Adjustment Controls
CAUTION:
RISK OF FIRE. USE ONLY 1500 WATT, H TYPE 100V METAL HALIDE LAMP,
SFc10-4 BASE.
ATTENTION:
RISQUE D'INCENDIE. UTILISER UNIQUEMENT UNE LAMPA HALOGENE EN METAL DE
TYPE H, 1500 WATT, 100V ET UN SUPPORT SFc10-4.
CAUTION:
RISK OF EXPOSURE TO EXCESSIVE ULTRAVIOLET RADIATION. DO NOT OPERATE
WITHOUT COMPLETE LAMP ENCLOSURE IN PLACE OR WHEN LENS IS DAMAGED.
DISCONNECT FIXTURE
BEFORE RELAMPING
CAUTION:
HOT LAMP
DO NOT
OPEN FOR 5 MINUTES
AFTER SWITCHING OFF.
Y
Z
1
X
5