Philips VL3015LT Service Manual page 54

Spot luminaire
Hide thumbs Also See for VL3015LT:
Table of Contents

Advertisement

VARI
LITE - VL3015LT S
36
L
S
POT
UMINAIRES
ERVICE
Lens Group A Motor Cable
The motor cable for lens group A should be tied directly off onto the
mount. There should be slack.
Lens Group Motor Cables
Tie off along mount as shown. When all lenses are pushed back, a little
slack should still exist in cables to allow free mechanism movement. If
cables are pulled tight, the lenses may not calibrate correctly.
The cable harness should be neatly tied along the inside of the mount. Tie
down tightly so harness cannot be snagged by lens groups.
Tied tightly
to bulkhead
Cables routed to
back of lens group
Cables secured using
both cable saddles
Slack for free lens movement
M
ANUAL
Frost Motor and Sensor Cables
All cables should be routed to the back of the
lens group. Frost motor and sensor cables
should be neatly routed over the lens using
the wire tie holes on the plate. Both cable tie
saddles should be used to secure cables on
lens carrier. Cables should be tight along
lens group so they do not fall into the beam.
Slack should be left at bottom so lens group
can travel freely.
02 .9 698.00 10 0