Removing the actuator from the valve
1.
2.
3.
4.
5.
6.
Figure 16
Decommission (Out of Service)
Disconnect all air supply hoses (Ports A and B or solenoid).
Disconnect all electrical wirings of the switch box.
Disconnect the electrical wiring of the solenoid valve.
Remove the bolts and nuts from the valve flange.
Remove the bracket from the actuator.
Remove the switch box and solenoid valve. Refer to the documentation of the
switch box and solenoid valve for safe disassembly.
Removing actuator from valve
3
2
4
Section 7: Decommission (Out of Service)
1
September 2017
25