IDENTIFICATION OF ELECTRICAL
B
10
CHECKING THE SIGNAL SYSTEM
1 Horn switch
• Disconnect the nine core connector of the left side
switch.
• Connect Tester ( ) to the connector
• Press the button (Horn) to activate the horn
• Check continuity between the cables as follows:
Terminal (+)
Orange lead (1)
Terminal (-)
Light blue lead (2)
Button pressed
Continuity
Button not pressed
No continuity
1
CORRECT
05188075
SYSTEM FAILURES
SIGNAL SYSTEM
THE HORN DOES NOT WORK
2
26
INCORRECT
Horn switch faulty
03/06
DRAKON 50 NKD
Replace the left switch.