Line distance protection REL670 2.2
Product version: 2.2
Table 198. Impedance functions, alternatives
Function
Note: One and only one of alternatives 1 to 6 must be selected. *) Selected qty = 0 for functions in unselected alternatives.
Alternative 1 Distance protection, quadrilateral
Distance protection zone, quadrilateral characteristic
Directional impedance quadrilateral
Phase selection, quadrilateral characteristic with fixed angle
Alternative 2 Distance protection for series compensated lines, quadrilateral
Phase selection, quadrilateral characteristic with fixed angle
Distance measuring zone, quadrilateral characteristic for series
compensated lines
Directional impedance quadrilateral, including series
compensation
Alternative 3 Distance protection, mho (mho for phase - phase fault and mho in parallel with quad for earth fault)
Full-scheme distance protection, mho characteristic
Full-scheme distance protection, quadrilateral for earth faults
Directional impedance element for mho characteristic
Additional distance protection directional function for earth faults
Mho impedance supervision logic
Faulty phase identification with load encroachment
Alternative 4 Distance protection, quadrilateral with separate settings for PP and PE
Directional impedance quadrilateral
Distance measuring zone, quad characteristic separate Ph-Ph
and Ph-E settings
Phase selection, quadrilateral characteristic with settable angle
Alternative 5 High speed distance protection, quadrilateral and mho
High speed distance protection, quad and mho characteristic
Alternative 6 High speed distance protection for series compensated lines, quadrilateral and mho
High speed distance protection for series comp. lines, quad and
mho characteristic
Optional with alternative 1
Directional impedance element for mho characteristic
Optional with alternative 3
Phase selection, quadrilateral characteristic with fixed angle
Optional with alternatives 1, 2 and 4
Additional distance protection directional function for earth faults
Faulty phase identification with load encroachment
Optional with alternatives 1, 2, 3 and 4
Phase preference logic
Optional with alternative 5 and 6
Phase preference logic
Optional with any alternative
Power swing detection
Automatic switch onto fault logic, voltage and current based
Power swing logic
PoleSlip/Out-of-step protection
Out-of-step protection
Table 199. Current protection
Position
1
2
3
C
00
ABB
4
5
6
7
8
9
Function
Ordering no
identification
ZMQPDIS,
1MRK005907-AA
ZMQAPDIS
ZDRDIR
1MRK005907-BA
FDPSPDIS
1MRK005907-CA
FDPSPDIS
1MRK005907-CA
ZMCPDIS,
1MRK005907-DA
ZMCAPDIS
ZDSRDIR
1MRK005907-EA
ZMHPDIS
1MRK005907-FA
ZMMPDIS,
1MRK005907-GA
ZMMAPDIS
ZDMRDIR
1MRK005907-HA
ZDARDIR
1MRK005907-KA
ZSMGAPC
1MRK005907-LB
FMPSPDIS
1MRK005907-MA
ZDRDIR
1MRK005907-BA
ZMRPDIS,
1MRK005907-NA
ZMRAPDIS
FRPSPDIS
1MRK005907-PA
ZMFPDIS
1MRK005907-SC
ZMFCPDIS
1MRK005907-RC
ZDMRDIR
1MRK005907-HA
FDPSPDIS
1MRK005907-CA
ZDARDIR
1MRK005907-KA
FMPSPDIS
1MRK005907-MA
PPLPHIZ
1MRK005908-DB
PPL2PHIZ
1MRK005908-DC
ZMRPSB
1MRK005907-UA
ZCVPSOF
1MRK005908-AA
PSLPSCH
1MRK005907-VA
PSPPPAM
1MRK005908-CB
OOSPPAM
1MRK005908-GA
10
11
12
13
14
0
00
1MRK 506 372-BEN -
Position
Available
Selected
qty
qty
1
1-5 *)
2
1-2 *)
3
2 *)
3
2 *)
4
1-6 *)
5
1-2 *)
6
1-5 *)
7
1-5 *)
8
1-2 *)
9
1-2 *)
10
1 *)
11
2 *)
2
1-2 *)
12
1-5 *)
13
2 *)
14
1-2 *)
15
1-2 *)
8
0-2
3
0-2
9
0-2
11
0-2
16
0-1
17
0-1
18
0-1
19
1
20
0-1
21
0-2
22
0-1
15
16
17
18
19
20
1
0
0
0
Notes and rules
21
22
23
0
0
129